cFP-RLY-423

CE Compliance

This product meets the essential requirements of applicable 
European Directives, as amended for CE marking, as follows:

Low-Voltage Directive (safety)......... 73/23/EEC

Electromagnetic Compatibility 
Directive (EMC) ............................... 89/336/EEC

Note

Refer to the Declaration of Conformity (DoC) for 

this product for any additional regulatory compliance 
information. To obtain the DoC for this product, 
click

Declarations of Conformity Information

 at 

ni.com/hardref.nsf/

.

Where to Go for Support

For more information about setting up the FieldPoint system, refer 
to these National Instruments documents:

FieldPoint network module user manual 

Other FieldPoint I/O module operating instructions

FieldPoint connector block operating instructions

Go to 

ni.com/support

 for the most current manuals, examples, 

and troubleshooting information. 

For telephone support in the United States, create your service 
request at 

ni.com/support

 and follow the calling instructions 

or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20,  Brazil 55 11 3262 3599, 
Canada (Calgary) 403 274 9391, 
Canada (Montreal) 514 288 5722, 
Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, 
Canada (Toronto) 905 785 0085, 
Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, 
Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, 
India 91 80 51190000,  Israel 972 0 3 6393737, 
Italy 39 02 413091,  Japan 81 3 5472 2970, 
Korea 82 02 3451 3400, Malaysia 603 9131 0918, 
Mexico 001 800 010 0793, Netherlands 31 0 348 433 466, 
New Zealand 0800 553 322,  Norway 47 0 66 90 76 60, 

Содержание FieldPoint cFP-RLY-423

Страница 1: ...RLY 423 is a Compact FieldPoint relay output module with the following features Four single pole double throw SPDT relay channels Switches up to 1 5 A at 35 VDC or 250 VAC LED relay status indicators...

Страница 2: ...ent backward insertion 2 Press firmly to seat the cFP RLY 423 on the backplane 3 Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the captive screws to 1 1 N...

Страница 3: ...peak or 60 VDC Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards Each relay channel of the cFP RLY 423 has four terminals one...

Страница 4: ...loads and an external power supply to one channel of the cFP RLY 423 as shown in Figure 2 Install a 1 5 A 250 V maximum fast acting fuse suitable for the load at the connected IC terminal to protect...

Страница 5: ...are connected to the relays a large counter electromotive force can occur at relay switching time because of the energy stored in the inductive load These flyback voltages can severely damage the rel...

Страница 6: ...e the circuit you are planning to use Diode and Zener Diode Circuit Diode Circuit 1 This section has been reprinted with permission from American Zettler Inc Diagram Notes Use in DC applications only...

Страница 7: ...hould be smaller than that of the CR circuit Do not utilize for timer loads as leakage current can cause faulty operations Circuit B is suitable for AC or DC If the load is a relay or solenoid release...

Страница 8: ...Isolation and Safety Guidelines Caution Read the following information before attempting to connect the cFP RLY 423 to any circuits that may contain hazardous voltages This section describes the isola...

Страница 9: ...al supply voltages the V and C terminals with other devices including other FieldPoint devices unless those devices are isolated from human contact You must connect the protective earth PE ground term...

Страница 10: ...llation Category II is for measurements performed on circuits directly connected to the electrical distribution system This category refers to local level distribution such as that provided by a stand...

Страница 11: ...operations min Electrical 1 105 operations at rated resistive load Maximum switching frequency Mechanical 20 operations per second Electrical 1 operation per second at maximum load Relay operate time...

Страница 12: ...r altitudes the isolation voltage ratings must be lowered Pollution Degree 2 Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for...

Страница 13: ...for the most current manuals examples and troubleshooting information For telephone support in the United States create your service request at ni com support and follow the calling instructions or d...

Страница 14: ...0 311 210 Russia 7 095 783 68 51 Singapore 65 6226 5886 Slovenia 386 3 425 4200 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 200 51 51 Taiwan 886 2 252...

Страница 15: ...com are trademarks of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments...

Отзывы: