30
|
ni.com
|
GPIB Hardware Installation Guide and Specifications
Environment
Operating ambient temperature
0 °C to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity
10% to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage ambient temperature
-40 °C to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Storage relative humidity
5% to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Shock and Vibration
Operating shock
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27;
test profile developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating
5 Hz to 500 Hz, 0.31 g
rms
Nonoperating
5 Hz to 500 Hz, 2.46 g
rms
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
PXI-GPIB
Performance
GPIB
3-wire
up to 1536 kbytes/s
HS488
up to 7885 kbytes/s
Power Requirements
+5 V
80 mA, Typical
165 mA, Maximum
VIO
3 mA, Typical
10 mA, Maximum