1.
Launch MAX on the host computer.
2.
Expand
Remote Systems
in the configuration tree and locate your system.
3.
Select your target.
Tip
MAX lists the system under the model number followed by the serial
number, such as NI-CRIO-9067-1856AAA.
Setting a System Password
Complete the following steps to set a system password.
Note
The default username for the cRIO-9067 is
admin
. There is no default
password for the cRIO-9067, so you must leave the password field blank when
logging in until you set a system password.
1.
Right-click your system and select
Web Configuration
.
The NI Web-Based Configuration and Monitoring utility opens in your default browser
and is where you set the password. If you have not installed Microsoft Silverlight,
NI Web-based Configuration & Monitoring prompts you to do so.
2.
Enter a unique name for your system in the
Hostname
field.
3.
Click the
Security Configuration
icon.
4.
Click
Login
.
5.
In the
Login
dialog box, enter the username
admin
and leave the password field blank.
6.
Click
OK
.
7.
Click
Change Password
.
8.
Enter and re-enter a new password.
9.
Click
OK
.
10. Click
Save
.
11. Click
OK
to confirm you are changing the password.
Caution
NI cannot recover lost system passwords. If you forget the password,
you must contact NI and reformat the controller.
Installing Software on the cRIO-9067
Complete the following steps to install software on the cRIO-9067.
1.
In MAX, expand your system under Remote Systems.
2.
Right-click
Software
.
3.
Select
Add/Remove Software
to launch the LabVIEW Real-Time Software Wizard.
Tip
You must log in if you set a system password.
4.
Select the recommended software set for your LabVIEW and NI-RIO Device Drivers
versions.
5.
Click
Next
.
NI cRIO-9067 Getting Started Guide
|
© National Instruments
|