Contact Closure Information
Our systems are able to be integrated via Contact Closure through the use of a 3-Wire RJ45 Cable. Use the
following information for wiring the to your Control System.
Green
is UP (Pin 3)
Red
is DOWN (Pin 5)
Blue
is GROUND (Pin 8)
You will need (2) Normally Open Relays, one for UP and one for DOWN. Each relay should receive a
momentary pulse of 750ms to 1000ms. Do not latch a contact closure command as this will cause intermittent
function on the system and potentially damage the Control Box.
Note:
You cannot use both IR and Contact Closure or RF and Contact Closure at the same time as this may
cause intermittent function on the system.