TERMINAL
NUMBER
DESCRIPTION
1
230V phase power supply
2
230V neutral power supply
3
230V phase (for accessories power supply)
4
230V neutral (for accessories power supply)
5
Motor ouput, close (L)
6
Motor output, common (N)
7
Motor ouput, open (L)
8
230V phase (for accessories power supply)
9
230V neutral (for accessories power supply)
10
+ output led
11
+ output led
12*
OUT led 1 (-)
13*
OUT led 2 (-)
14*
OUT led 3 (-)
15
Not used
16*
Input 2: default= rain sensor
17
433,92MHz antenna signal
18
Not used
19
Not used
20
Led power (12 or 24Vdc)
21
Led power supply -
22
Input common
23*
Input 1: default= vento
3 - LED OUTPUT ELECTRICAL CONNECTIONS
This control unit can manage 1, 2 or 3 lines of single-colour LED strip lights.
By default, operation is set to one li strip lights. If a different strip type is used, follow the paragraph 2.4 procedure.
3.1 CONNECTING ONE LINE OF SINGLE-COLOUR STRIP LIGHTS
With the default settings the control unit is set to control the three LED lines with synchronized operation.
WARNING:
•
Connect up to 5A per output and max total 10A
•
The outputs are synchronized
•
The operation of the inputs can be set, see paragraph 6.4
L
L N
(out)
(in)
(out)
N
L
POWER SUPPLY
12 O 24VDC
N
17 18 19 20 21 22
10 11 12 13 14 15 16
23
1
2
3
4
5
6
7
8
9
-
+
(10)
+
(11)(12)
-
-
(13)(14)
(20)
(21)
(9)
(8)
SINGLE COLOR LED
Synchronized function
5