4

2. PSUs: Slide the PSU into its slot, push the latch handle in to seat it, then tighten the retining bolt.

NOTE: 

Do not connect the power cords to the PSUs at this time.

Load Disk Drives

1. Pull the unit forward until there is enough room to remove the top cover.

2. Unscrew the retaining screws for the front panel (one on each side), then pull the front panel down.

3. Open the drive drawer lid.

4. Starting at the front of the drawer, and using the drive guides to help you orient the disks, carefully 

load each disk drive into a drive slot. Make sure that each disk is fully seated and that the drive 
ejection handles are flat against each drive.

5. Replace the top cover, close the front face, and replace the front panel retaining screws.

6. Slide the unit back into the rack.

7. Using the supplied bolts, bolt the face of the SATABeast/SASBeast unit to the rack.

CAUTION: 

Always load disk drives in rows of fourteen. Leaving large gaps between 

disk drives decreases cooling efficiency and may result in some disk drives 
overheating.