SAFETY  INSTRUCTIONS:

SAVE THESE INSTRUCTIONS 

- This manual contains 

important safety and operating instructions for the 
NexPump. Follow these important safety precautions. 
Failure to follow safety precautions can result in personal 
injury or damage to the NexPump.

CAUTION - To reduce the risk of injury, charge only
lead type rechargeable batteries. Other types of
batteries may burst causing personal injury and damage. 

Do not expose the NexPump System Unit to rain or snow.

Do not install the NexPump System Unit where 
temperatures will be below freezing (32 degrees 
Fahrenheit).

Do not charge a battery that may be frozen. Allow battery 
to sit at room temperature before connecting to the 
NexPump.

If an extension cord must be used, make sure 
    A: That the pins on the plug or extension cord are the
         same number, size and shape as those of the    
         plug  on the NexPump System Unit. 
    B: That the extension cord is properly wired and in
         good electrical condition.
    C: That the wire size is large enough for the AC        
         ampere rating of the NexPump System Unit.

Do not operate the NexPump System Unit if it has 
received a sharp blow, been dropped, or otherwise 
damaged in anyway; take it to a qualified serviceman.

Do not operate the NexPump System Unit with a damaged 
cord or plug – have them replaced or repaired immediately.

Do not disassemble the NexPump System Unit; take it to a 
qualified serviceman when service or repair is required. 
Disassembly  may result in a risk of electric shock or fire 
and void the warranty.

Never  pull directly on any wiring connected to pumps,
battery,  AC power or sensor. Disconnect by pulling on 
connectors only.

Never  force the connectors out of place, they should 
disconnect and connect easily. Some connectors have 
safety latches, so make sure they are depressed.

Never  attempt any maintenance and/or cleaning with the 
NexPump powered up. Risk of electric shock may result.

WARNING - RISK OF EXPLOSIVE GASES
WORKING IN THE VICINITY OF A LEAD-ACID 
BATTERY CAN BE DANGEROUS.
BATTERIES GENERATE EXPLOSIVE GASES 
DURING NORMAL BATTERY OPERATION.

FOR THIS REASON, IT IS OF THE UTMOST 
IMPORTANCE THAT EACH TIME BEFORE
USING YOUR NEXPUMP CONTROL UNIT YOU 
READ THIS MANUAL AND FOLLOW THE 
INSTRUCTIONS EXACTLY.

Be sure the area around the battery is well
ventilated. 

A SPARK NEAR THE BATTERY MAY
CAUSE AN EXPLOSION.

PERSONAL PRECAUTIONS:

If LEAD-ACID Battery is used
Someone should be within range of your voice and/or 
close enough to come to your aid when you work near a 
lead-acid battery.

Have plenty of fresh water and soap nearby in
case battery acid contacts skin, clothing or eyes.

Wear complete eye protection and clothing
protection. Avoid touching your eyes while
working near the battery.

If battery acid contacts skin and/or clothing, wash 
immediately with soap and water. If acid enters the
eye, immediately flood eye with running cold water for at 
least 10 minutes and get medical attention immediately. 

When the battery fluid level is low, add distilled water in 
each cell until the level reaches the
indicator on each cell. Do not overfill.

Precautions for all Batteries:

NEVER smoke or allow a spark or flame in the vicinity of 
the battery.

Be extra cautious to reduce the risk of dropping a metal 
tool onto the battery. It might spark or short-circuit the 
battery or another electrical part that may cause an 
explosion.

Remove personal metal items such as rings, bracelets, 
necklaces and/or watches when working with a battery. A 
battery can produce a short-circuit current high enough to 
weld a ring (or the like) to metal, causing a severe burn.

When Cleaning the battery terminals. Be careful to keep 
corrosion from coming in contact with eyes.

Do not  use the system unit for charging Dry-Cell batteries, 
that are most commonly used with household appliances. 
These batteries may burst and cause injury to persons and 
damage to property.

3

Содержание Ai Single

Страница 1: ...Phone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Users Manual 4 00 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2013 NexPump Inc...

Страница 2: ...1 Surge Protector Supplied With Phone Line Notification Qty 1 Owners Manual Purchased Separately Required to operate 1 Deep Cycle Marine Battery See Appendix for more information You will also need t...

Страница 3: ...h the NexPump powered up Risk of electric shock may result WARNING RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OFA LEAD ACID BATTERY CAN BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORM...

Страница 4: ...NexPump System Unit connects to the NEGATIVE post of the battery The RED wire from the NexPump System Unit connects to the POSITIVE post of the battery The REVERSE POLARITY LED will illuminate if the...

Страница 5: ...sor 1 is the main sensor and will turn on the pump s when the water rises above the sensor The Gray Sensor should be used for Sensor 1 Sensor 2 does not operate exactly like Sensor 1 however functions...

Страница 6: ...the bottom of the connector and pull out the connector To disconnect a sensor connector slightly depress the security latch on the right side of the connector and pull out the connector Step 5 Connec...

Страница 7: ...in down position The letter B will be blinking in the mode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manua...

Страница 8: ...Silence alarm Re Enables Alarm that was already Silenced T Run Manual Test K Runs Configuration Menu I Runs Stats Information Menu D Disable Alarm This will totally disable the alarm in the NexPump Un...

Страница 9: ...if needed When disabled the alarm will not sound for any reason The alarm will be disabled for five 5 days and automatically enabled after that time You can Enable the Alarm before the five 5 Day per...

Страница 10: ...s have a lifespan and should be replaced when the NexPump reports this time frame has expired This should also be reset when replacing batteries Defaults for battery type selected WET 1300 Days 3 5 Ye...

Страница 11: ...ineral content may be used NEVER ADD MORE ACID Fill the battery cell so water is just below the fill cap Clean Battery Posts as needed with a 50 50 solution of water and baking soda or a wire brush Do...

Страница 12: ...obstructions In the winter it may indicate a frozen discharge pipe V or v Vapor Lock Condition This alert indicates there may be air trapped in the discharge plumbing It may also indicate Sensor 1 is...

Страница 13: ...s NONE Charger System Operation Charge Rate Ai Extreme Ai Dual 20 Amps Ai Single 10 Amps The charging circuit is disabled anytime the battery or electric power is disconnected or if both pumps are ope...

Страница 14: ...nd wires are attached to each connector If the sensors are connected correctly the sensor may be defective AC POWER Input Power Identifiers O AC Power is Off I AC Power is On Note If identifier is bli...

Страница 15: ...ckup VRef if this alert is detected If Notification is Installed Notification will occur on a Primary VRef Alert after approximately five 5 Minutes Clear Primary VRef Alerts Primary VRef Alerts will c...

Страница 16: ...rState SRM 27B Group 27 DC 105 A H SRM 29 Group 29HM DC 120 A H Multiple Batteries Two Batteries may be connected in PARALLEL to increase time on battery power This configuration is highly recommended...

Страница 17: ...Resets in 5 days F Charge Status Off Charge Off Fxx Full Mode Txx Trickle Mode Mxx Maintain Mode Dis Charge Disabled ttS Seconds Until Charge System Starts Fl_ Charge System Failed _ indicates the al...

Страница 18: ...rial number is located on the rear unit or proceed to step 2 2 Press Function Button Until K appears 9 seconds 3 Release Function Button 4 Display shows SN Retrieve Firmware Revision 1 Press Function...

Страница 19: ...e or Ultra Capacity pumps that have exceeded 1200 0 hours of operating time and does not cover equipment which had been tampered with in any way or to damage caused by accident negligence alteration m...

Страница 20: ...20 Diagram A Ai Turbo or Ai Dual Installed as only pump Operating in Primary Mode...

Страница 21: ...21 Diagram B Ai Rage Ai Turbo or Ai Dual Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Страница 22: ...22 Diagram C Ai Single or Ai Jet Installed with existing pump Operating in Backup Mode ONLY...

Отзывы: