NexPump Ai Single Скачать руководство пользователя страница 19

LIMITED WARRANTY:

     This NexPump, Inc. product is warranted against 
defects in workmanship and materials. If any failure of 
these components, resulting from a defect in either 
workmanship or material shall occur under normal use 
within THREE YEARS (3) from the original date of 
purchase for Ai Extreme Series Pumps and Ai Dual or 
under normal use within TWO YEARS (2) from the 
original date of purchase for the Ai Single, such failure 
shall be corrected free of charge to the original purchaser 
by repair or, at NexPump's sole option, replacement of the 
defective part or parts.

      No charge shall be made for labor or services 
performed during the said warranty period providing the 
defective product is sent prepaid to our Authorized Service 
Station.  NexPump, Inc. will either repair or at its sole 
option, replace any such part except for fuses, circuit 
breakers under normal and proper use.  This warranty does 
not cover High Capacity pumps that have exceeded 2500.0 
hours of operating time or Ultra Capacity pumps that have 
exceeded 1200.0 hours of operating time and does not 
cover equipment, which had been tampered with in any 
way, or to damage caused by accident, negligence, 
alteration, misapplication or natural disasters.
      This product must be returned transportation prepaid, 
properly packed and insured.  NexPump, Inc. bears 
transportation cost of the repaired product back to the 
purchaser.  This warranty applied only to the original 
purchaser.

     NO OTHER WARRANTIES ARE EXPRESSED OR 
IMPLIED.  NEXPUMP, INC. IS NOT LIABLE FOR 
CONSEQUENTIAL DAMAGES.

       EXCEPT AS SET FORTH HEREIN, THERE ARE 
NO WARRANTIES, EXPRESS OR IMPLIED, WITH 
RESPECT TO NEXPUMP PRODUCTS. NEXPUMP, 
INC. EXPRESSLY EXCLUDES AND DISCLAIMS ANY 
IMPLIED WARRANTY OF MERCHANTABILITY AND 
ANY WARRANTIES OF FITNESS FOR A 
PARTICULAR PURPOSE, APPLICATION OR USE. 
UNDER NO CIRCUMSTANCES WILL THE COMPANY 
BE LIABLE FOR SPECIAL, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES, WHETHER SUCH 
DAMAGES ARE SOUGHT IN CONTRACT, IN TORT 
(INCLUDING BUT NOT LIMITED TO NEGLIGENCE 
AND STRICT LIABILITY) OR OTHERWISE, AND 
THE COMPANY'S LIABILITY SHALL IN NO EVENT 
EXCEED THE PURCHASE PRICE OF THE NEXPUMP 
PRODUCTS ON WHICH SUCH LIABILITY IS BASED.

19

Содержание Ai Single

Страница 1: ...Phone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Users Manual 4 00 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2013 NexPump Inc...

Страница 2: ...1 Surge Protector Supplied With Phone Line Notification Qty 1 Owners Manual Purchased Separately Required to operate 1 Deep Cycle Marine Battery See Appendix for more information You will also need t...

Страница 3: ...h the NexPump powered up Risk of electric shock may result WARNING RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OFA LEAD ACID BATTERY CAN BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORM...

Страница 4: ...NexPump System Unit connects to the NEGATIVE post of the battery The RED wire from the NexPump System Unit connects to the POSITIVE post of the battery The REVERSE POLARITY LED will illuminate if the...

Страница 5: ...sor 1 is the main sensor and will turn on the pump s when the water rises above the sensor The Gray Sensor should be used for Sensor 1 Sensor 2 does not operate exactly like Sensor 1 however functions...

Страница 6: ...the bottom of the connector and pull out the connector To disconnect a sensor connector slightly depress the security latch on the right side of the connector and pull out the connector Step 5 Connec...

Страница 7: ...in down position The letter B will be blinking in the mode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manua...

Страница 8: ...Silence alarm Re Enables Alarm that was already Silenced T Run Manual Test K Runs Configuration Menu I Runs Stats Information Menu D Disable Alarm This will totally disable the alarm in the NexPump Un...

Страница 9: ...if needed When disabled the alarm will not sound for any reason The alarm will be disabled for five 5 days and automatically enabled after that time You can Enable the Alarm before the five 5 Day per...

Страница 10: ...s have a lifespan and should be replaced when the NexPump reports this time frame has expired This should also be reset when replacing batteries Defaults for battery type selected WET 1300 Days 3 5 Ye...

Страница 11: ...ineral content may be used NEVER ADD MORE ACID Fill the battery cell so water is just below the fill cap Clean Battery Posts as needed with a 50 50 solution of water and baking soda or a wire brush Do...

Страница 12: ...obstructions In the winter it may indicate a frozen discharge pipe V or v Vapor Lock Condition This alert indicates there may be air trapped in the discharge plumbing It may also indicate Sensor 1 is...

Страница 13: ...s NONE Charger System Operation Charge Rate Ai Extreme Ai Dual 20 Amps Ai Single 10 Amps The charging circuit is disabled anytime the battery or electric power is disconnected or if both pumps are ope...

Страница 14: ...nd wires are attached to each connector If the sensors are connected correctly the sensor may be defective AC POWER Input Power Identifiers O AC Power is Off I AC Power is On Note If identifier is bli...

Страница 15: ...ckup VRef if this alert is detected If Notification is Installed Notification will occur on a Primary VRef Alert after approximately five 5 Minutes Clear Primary VRef Alerts Primary VRef Alerts will c...

Страница 16: ...rState SRM 27B Group 27 DC 105 A H SRM 29 Group 29HM DC 120 A H Multiple Batteries Two Batteries may be connected in PARALLEL to increase time on battery power This configuration is highly recommended...

Страница 17: ...Resets in 5 days F Charge Status Off Charge Off Fxx Full Mode Txx Trickle Mode Mxx Maintain Mode Dis Charge Disabled ttS Seconds Until Charge System Starts Fl_ Charge System Failed _ indicates the al...

Страница 18: ...rial number is located on the rear unit or proceed to step 2 2 Press Function Button Until K appears 9 seconds 3 Release Function Button 4 Display shows SN Retrieve Firmware Revision 1 Press Function...

Страница 19: ...e or Ultra Capacity pumps that have exceeded 1200 0 hours of operating time and does not cover equipment which had been tampered with in any way or to damage caused by accident negligence alteration m...

Страница 20: ...20 Diagram A Ai Turbo or Ai Dual Installed as only pump Operating in Primary Mode...

Страница 21: ...21 Diagram B Ai Rage Ai Turbo or Ai Dual Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Страница 22: ...22 Diagram C Ai Single or Ai Jet Installed with existing pump Operating in Backup Mode ONLY...

Отзывы: