BATTERY STATUS:

Battery Status:
‘XX.XX’

 Battery  voltage

Normal readings ‘12.40-13.20’ (Charger Off)

‘Disc’

  Battery disconnected

Displays when Battery is disconnected or Battery voltage 
is below 1.50 volts

‘Rep_’

  Replace Battery

 (The ‘_ ‘ indicates the reason for failure “numeric value”)
See (Battery Troubleshooting)

If Notification is Installed:

Notification will occur on a Battery Disconnected or Low 
Battery or Battery Replacement Alert after approximately 
five (5) Minutes. After an AC Power Outage when running 
on Battery, Notification will occur after approximately 
thirty (30) Minutes.

Clear Battery Alerts:

Only Battery Replacement Alerts can be cleared. To Clear 
a Battery Replacement Alert, use Function 

'C'

Testing:

Battery is tested on 12 Hour Self-Tests or Manual Tests. 
Exceptions: Charge System is Active, Battery Disconnect,
Battery Replacement Alert is Active.

Menu Options for  Battery Operations:

Function 'K' Battery Operations:

Menu Item to set or reset Battery Amp Hours:

(Set Total Amp Hours of Batteries Connected. Press and 
hold Function Button at this menu, number will increment 
by 5. Release at desired amount. Defaults to 105 AH)

Menu Item to turn on Battery Charger:

(Turn on Charger when system is first installed or when 
replacing Batteries. Press and hold Function Button at this 
menu, cursor will toggle between 'Y' and 'N'. Release at 
desired position)

Menu Item to reset Battery Life Timer:

(Batteries have a lifespan and should be replaced when the 
NexPump reports this time frame has expired. This should 
also be reset when replacing batteries. Defaults for battery 
type selected. WET = '1300 Days, 3.5 Years', AGM = 
'1600 Days, 4.5 Years'')

Menu Item for Battery Type:

(Select Battery Type to type installed. Press and hold 
Function Button at this menu, cursor will toggle between 
'W' and 'A'. Release at desired position)

Function 'I' Battery Operations:

Info Item to check Battery Amp Hours and Type:

BA=Battery Amp\Hours, Batt=Battery Type

Running On Battery Power:

Location '(C) AC Power Status' above indicats an AC 
Power Loss 'O'. If the alarm is silenced this location will 
be blinking to indicate the alarm is silenced.  Location '(F) 
Battery Life' will indicate the Battery Life in Hours 
Remaining when AC Power fails. ‘999’ Hours is the 
maximum number displayed.  The Battery Life Monitor 
calculates the remaining life about 4 times an hour. When 
running on battery power you should closely monitor the 
Battery Life when the Hours Indicated are ten (10) or 
below.  Fluctuating pump(s) times, battery condition and 
battery state before going to battery power will affect the 
calculated time throughout the power loss, in addition this 
number may not be accurate if the Battery Amps Hours are 
not set correctly before the Power Outage began. The 
alarm will also sound from the loss of electric power, 
which  may silenced by performing a Function 'S'. Once 
AC power is restored the display will again display a 
normal status. A charge cycle may also be enabled at the 
time AC Power is restored.

10

(E) Battery or Notification Status

Содержание Ai Single

Страница 1: ...Phone 630 365 4NEX 4639 Fax 630 365 6919 Email support nexpump com Web Address www nexpump com Users Manual 4 00 0002 NexPump is a Registered Trademark of NexPump Inc Copyright 2003 2013 NexPump Inc...

Страница 2: ...1 Surge Protector Supplied With Phone Line Notification Qty 1 Owners Manual Purchased Separately Required to operate 1 Deep Cycle Marine Battery See Appendix for more information You will also need t...

Страница 3: ...h the NexPump powered up Risk of electric shock may result WARNING RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OFA LEAD ACID BATTERY CAN BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORM...

Страница 4: ...NexPump System Unit connects to the NEGATIVE post of the battery The RED wire from the NexPump System Unit connects to the POSITIVE post of the battery The REVERSE POLARITY LED will illuminate if the...

Страница 5: ...sor 1 is the main sensor and will turn on the pump s when the water rises above the sensor The Gray Sensor should be used for Sensor 1 Sensor 2 does not operate exactly like Sensor 1 however functions...

Страница 6: ...the bottom of the connector and pull out the connector To disconnect a sensor connector slightly depress the security latch on the right side of the connector and pull out the connector Step 5 Connec...

Страница 7: ...in down position The letter B will be blinking in the mode position on display o NexPump WILL display and sound an alarm if pump s are activated Indicated by A in the corresponding pump location Manua...

Страница 8: ...Silence alarm Re Enables Alarm that was already Silenced T Run Manual Test K Runs Configuration Menu I Runs Stats Information Menu D Disable Alarm This will totally disable the alarm in the NexPump Un...

Страница 9: ...if needed When disabled the alarm will not sound for any reason The alarm will be disabled for five 5 days and automatically enabled after that time You can Enable the Alarm before the five 5 Day per...

Страница 10: ...s have a lifespan and should be replaced when the NexPump reports this time frame has expired This should also be reset when replacing batteries Defaults for battery type selected WET 1300 Days 3 5 Ye...

Страница 11: ...ineral content may be used NEVER ADD MORE ACID Fill the battery cell so water is just below the fill cap Clean Battery Posts as needed with a 50 50 solution of water and baking soda or a wire brush Do...

Страница 12: ...obstructions In the winter it may indicate a frozen discharge pipe V or v Vapor Lock Condition This alert indicates there may be air trapped in the discharge plumbing It may also indicate Sensor 1 is...

Страница 13: ...s NONE Charger System Operation Charge Rate Ai Extreme Ai Dual 20 Amps Ai Single 10 Amps The charging circuit is disabled anytime the battery or electric power is disconnected or if both pumps are ope...

Страница 14: ...nd wires are attached to each connector If the sensors are connected correctly the sensor may be defective AC POWER Input Power Identifiers O AC Power is Off I AC Power is On Note If identifier is bli...

Страница 15: ...ckup VRef if this alert is detected If Notification is Installed Notification will occur on a Primary VRef Alert after approximately five 5 Minutes Clear Primary VRef Alerts Primary VRef Alerts will c...

Страница 16: ...rState SRM 27B Group 27 DC 105 A H SRM 29 Group 29HM DC 120 A H Multiple Batteries Two Batteries may be connected in PARALLEL to increase time on battery power This configuration is highly recommended...

Страница 17: ...Resets in 5 days F Charge Status Off Charge Off Fxx Full Mode Txx Trickle Mode Mxx Maintain Mode Dis Charge Disabled ttS Seconds Until Charge System Starts Fl_ Charge System Failed _ indicates the al...

Страница 18: ...rial number is located on the rear unit or proceed to step 2 2 Press Function Button Until K appears 9 seconds 3 Release Function Button 4 Display shows SN Retrieve Firmware Revision 1 Press Function...

Страница 19: ...e or Ultra Capacity pumps that have exceeded 1200 0 hours of operating time and does not cover equipment which had been tampered with in any way or to damage caused by accident negligence alteration m...

Страница 20: ...20 Diagram A Ai Turbo or Ai Dual Installed as only pump Operating in Primary Mode...

Страница 21: ...21 Diagram B Ai Rage Ai Turbo or Ai Dual Installed with existing pump Operating in Primary or Backup Mode Recommended Configuration...

Страница 22: ...22 Diagram C Ai Single or Ai Jet Installed with existing pump Operating in Backup Mode ONLY...

Отзывы: