background image

 

PRESET

 

GEOM10 

 

Page 11/17

 

o

  Possibilities to use 2-3Box setup in stack configuration using MSUB15 in OMNI or CARDIO mode with 1 Back 

and 2 front and 3 GEOM10 on top of them, application venue up to 15 meters, default cross over 85 Hz but 
small overlap could have impact if needed, for example (MSUB15 120 Hz and GEOM10 75 Hz). 

 

 

 

 

 

4 - 6 Boxes 

o

  For  long  throw  flying  application  used  in  GEOM10  at  63  Hz  without  Sub  and  GEOM10  at  85  Hz  with  flying 

MSUB15 in cardio mode at 95 Hz. 

  

 

 

Содержание GEO M1012

Страница 1: ...User manual DP2657 01a DI GEO M10 Series GEOM1012 GEOM1025 ...

Страница 2: ...y declaration We NEXO SA ZA DU PRE DE LA DAME JEANNE 60128 PLAILLY France Declare under our sole responsibility that the product Loudspeaker Type GEOM10 Serial number On the product Is in conformity with the provisions of the following 2006 95 CE Low Voltage Directive directive including all applicable amendments Applied rules and standards EN ISO 12100 EN 60065 Plailly February 07th 2017 Joseph C...

Страница 3: ... accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that it s height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered l...

Страница 4: ... pull AutoRigTM in auto lock position Position GEOM10 on top front points will lock automatically Ensure that all AutoRigTM systems are locked Back Unlock GEOM10 link bar Pull on the latch to engage the guide in the slot Adjust the angle with the quick release pin 0820AV ...

Страница 5: ...pull AutoRigTM and holding the knob AutoRigTM remains in the open position Back Remove the quick release pin 0820AV Unlock the GEOM10 link bar by pulling the latch SAFETY You can replace one of the four screws with an eyebolt M8 and use a sling apply thread lock on the eyebolt ...

Страница 6: ...plier All GEOM10 accessories have been designed so that cabinet are arrayed vertically GEOM10 horizontal assemblies as shown in figure below are UNSAFE and STRICTLY PROHIBITED VNT BUMPM10 Rated for a maximum of 12 GEOM10 or 8 MSUB15 Maximum quantity for flown vertical cluster is NGEOM10 1 5 NMSUB15 12 2 rigging points 2 points with retractable rings Usable with VNT EXBARM10 for a one rigging point...

Страница 7: ...RIES Page 7 17 VNT GSTKM10S VNT GSTKM10L VNT MNSTKM10 Rated for a maximum of 3 GEOM10 on the top of MSUB15 GMT LBUMPM10 Rated for a maximum of 12 GEOM10 Usable with GMT EXBARM10L for a one rigging point GMT EXBARM10L ...

Страница 8: ...Page 8 17 GEOM10 ACCESSORIES GMT FLGM10 Pair of flanges for 120 horizontal directivity No tools magnetic clamp GMT 3CASEM10 GMT 6CASEM10 ...

Страница 9: ...ser manual GEOM1012 I GEOM1025 I Connectors o GEOM1012t 1025t two NL4 connectors the 4 pins of the 2 sockets are connected in parallel within the enclosure o GEOM10 use 2 2 1 1 through Amplification o The GEOM10 cabinets MUST be used with a NEXO processor to handle EQ phase alignment crossover and excursion thermal protection for the system loudspeakers There are two NEXO processor series supporti...

Страница 10: ...ss at 63 75 85 95 or 120Hz o Setup for Stack Monitor with high pass at 63 75 or 85 Hz For the GEOM1025 with or without directivity flanges the following setups are available o Setup for one stand alone box with high pass at 63 75 85 95 or 120 Hz o Setup for 2 to 3 boxes with high pass at 63 75 85 95 or 120 Hz o Setup for Stack Monitor with high pass at 63 75 or 85 Hz 1 Box o Default Cross over on ...

Страница 11: ... and 2 front and 3 GEOM10 on top of them application venue up to 15 meters default cross over 85 Hz but small overlap could have impact if needed for example MSUB15 120 Hz and GEOM10 75 Hz 4 6 Boxes o For long throw flying application used in GEOM10 at 63 Hz without Sub and GEOM10 at 85 Hz with flying MSUB15 in cardio mode at 95 Hz ...

Страница 12: ...out Sub and 85 Hz with MSUB15 at 85 Hz 7 12 Boxes o For very long throw application used with Sub either ground stack or flying recommended MSUB15 cardioid mode cross over MSUB15 95 Hz and 12 GEOM10 cross over 75 Hz for maximum impact Don t forget to put HF Waveguide either to the exterior or the interior of the venue ...

Страница 13: ... not compatible with others o Used for high power stage Monitor DJ Monitor Drum Fill Stack side o Always use same cross over between GEOM10 and MSUB15 no overlap possible without doing phase adjustment by yourself o Very high LF headroom o Clarity adjustment using 3dB on ArrayEQ 75 Hz crossover default ...

Страница 14: ...Page 14 17 ARRAY EQ 7 ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEq values GEOM10 GEOM10 STACK MON ...

Страница 15: ...2 Spare parts MARK QUANTITY REFERENCE DESIGNATION 1 2 05LEXM1012 Lexan GEOM1012 black 2 05LEXM1012 PW Lexan GEOM1012 white 2 05LEXM1025 Lexan GEOM1025 black 2 05LEXM1025 PW Lexan GEOM1025 white 2 1 05LEXWAR Lexan Warning 3 1 05LEXRIG EXP Lexan Rigging Explain 4 1 05LEXRIG ANG Lexan Rigging Angles 5 1 05LEXCNX M1012 Lexan CNX GEOM1012 1 05LEXCNX M1025 Lexan CNX GEOM1025 6 1 05HPADE68 16 HF Driver c...

Страница 16: ...langes GMT FLGM10 Crossover Frequency LF HF 1 3kHz Passive Nominal Impedance 8Ω Recommended Amplification 750 W per cabinet CARACTÉRISTIQUES Model GEOM10 Components LF 1x 10 8Ω Long excursion Neodymium driver with PDDTM HF 1 4 throat driver on a BEA FEA optimized HRWTM Material Lightweight polyurethane composite Finish Black or white structural paint Front finish Steel front grille Black or white ...

Страница 17: ...USER NOTES Page 17 17 10 USER NOTES France Nexo S A Parc d activité de la Dame Jeanne F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr https nexo sa com ...

Отзывы: