ems100
Product Manual, Issue 4
www.nexo.com
Page 53
5.3.20 Motion sensor enable (Sn)
Display
Description
Enables the input from the motion sensor.
Considerations
Must be disabled if a motion sensor is not fitted.
Range
00 (disabled) or 01 (enabled)
Global default
01 (enabled)
5.3.21 Display stability (d2)
Display
Description
Defines the rate of change of the displayed temperature.
Limiting the rate of change provides a dampening effect so as not to concern users
should the air temperature rise quickly due to a door opening.
Increasing the value for the display stability (d2) slows the rate of change of the
displayed temperature.
Considerations
Use the global default value for normal operation.
Range
1 to 254
Global default
46
5.3.22 Low voltage (LO)
Display
Description
Defines the minimum voltage allowed before switching off the compressor. The low
voltage (LO) values are 10% of the actual line in voltages (see table below).
Considerations
• Must not be used with an external voltage stabiliser
• Must only be used with an Elstat supplied transformer
Global default
0 (disabled)