6. Quick test

In order to test if the XZ Light sensor is installed correctly, please follow the test procedure below:

© 2021 Nexmosphere. All rights reserved. v1.0 / 08-21    

All content contained herein is subject to change without prior notice

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

PRODUCT MANUAL | XZ LIGHT SENSOR

7

Step 1 - Setup

First, connect the Light sensor to an Xperience 
controller. Secondly, power the Xperience controller. 

The green status LED of the XZ Light sensor should go 
on. The status LED of the controller will start to blink 
and once power-up is completed will be lit continuously.

Step 2 - Pick-up and place-back detection

Cover the light sensor to trigger a place-back. If the 
sensor is not yet installed behind a front panel, you 
can for example place the sensor with the bottom 

(flat) side on a table.

Both the green status LED of the sensor and the status 
LED of the controller should blink.

Uncover the light sensor to trigger a pick-up. If the 
sensor is not yet installed behind a front panel, you 

can rotate the sensor so that the bottom (flat) side is 

facing upwards and towards the light.

Both the green status LED of the sensor and the status 
LED of the controller should blink.

For a full test we recommend to connect the setup to 
a mediaplayer or PC and test all API commands listed 

in  this  document  (see  section  3,  page  2).  For  more 

information on how to setup a test for your controller, 
please see the Quick Start Guide of the Xperience 
controller you are using. These are available on 

nexmosphere.com/support-documentation

Please contact 

[email protected]

 for any

support questions you may have.

In case any of the steps above does not provide 
the expected result, please check the installation 
guidelines in this document. 

XN

Connect to powered 

USB port

XN

Connect to powered 

USB port

LED BLINK

LED BLINK

XN

Connect to powered 

USB port

LED BLINK

LED BLINK

Содержание XZ Series

Страница 1: ...e without prior notice 1 Table of content 1 General 1 2 Product overview 1 3 Functionality and API commands 2 3 1 Pick up and place back detection 2 3 2 Raw light measurement 2 4 Installation requirements and guidelines 3 4 1 Connection Diagrams 3 4 2 Hardware integration guidelines 3 4 3 Manual calibration 4 5 Settings 5 5 1 Settings 5 6 Quick test 7 XZ L20 Pick up detection light measurement Man...

Страница 2: ... when the object is placed back less light will reach the sensor and an API command is triggered as well These API messages have the following format 3 2 Raw light measurement The XZ Light sensor can also indicate the amount of light reaching the sensor as a raw decimal value The raw decimal value is a unfiltered direct AD conversion of the light measurement circuit and will therefore fluctuate We...

Страница 3: ... the double sided tape on the bottom flat side of the sensor A common thickness for the top panel is 3 5mm The thicker the top panel the less light will be able to reach the sensor especially when the top panel is made out of dark light absorbing material In these cases we recommend to either make sure there is a light source directly perpendicular above the sensor or increase the diameter of the ...

Страница 4: ...nsor may need to be calibrated again Measure raw light values 1 Set the sensor to Raw light values via setting 4 The command to do so is X001S 4 2 2 Place the object on the sensor Write down the value of the incoming API command For example X001A 30 3 Pick up the object from the sensor Write down the value of the incoming API command For example X001A 120 In case both values are very low e g 0 and...

Страница 5: ... to 4 3 the sensor will provide a trigger on pick up and place back of an object see page 2 Furthermore it will continuously auto calibrate by automatically adjusting the sensor s sensitivity setting 18 in such a way that in case of a place back the raw light value is between 0 25 setting 14 and in case of a pick up the raw light value is between 225 255 setting 15 For example in case the raw ligh...

Страница 6: ...same light conditions Example if the output of a raw light measurement is 0 and X is increased to 150 the Raw light value will increase e g to 20 So the more sensitive the higher the raw light value will be in the same light conditions When the sensor is set the auto calibration setting 4 3 thesensorwillcontinuouslyauto calibratebyautomatically adjusting the sensor s sensitivity setting 18 This is...

Страница 7: ...ble Both the green status LED of the sensor and the status LED of the controller should blink Uncover the light sensor to trigger a pick up If the sensor is not yet installed behind a front panel you can rotate the sensor so that the bottom flat side is facing upwards and towards the light Both the green status LED of the sensor and the status LED of the controller should blink For a full test we ...

Отзывы: