PRODUCT MANUAL | XZ LIGHT SENSOR

5.1 - Settings

The XZ Light sensor has multiple settings which determine the behaviour and output of the sensor. The settings can be 
adjusted by sending X-talk setting commands via the API. After a power cycle, the settings always return back to default.

X001S[1:1]

X001S[4:1]

X001S[10:

X

]

X001S[12:

X

]

X001S[11:

X

]

X001S[13:

X

]

X001S[1:2]

X001S[4:2]

X001S[4:3]

X001S[1:3]

X001S[1:4]

Setting 1: Status LED behaviour

1. LED on 

 

 

 

2. LED off  

 

 

3. LED on, blink at trigger (default)
4. LED off, blink at trigger  

Setting 4: Trigger mode

1. Pick-up/place-back detection (def) 

2. Raw light values
3. Pick-up/place back detection

     with auto-calibration (advanced)

Setting 10-13: Trigger ranges for Pick-up / Place-Back

 

Set lower value for place-back 

Set lower value for pick-up 

Set upper value for place-back 

Set upper value for pick-up 

Default, X is set to 

0

 

Default, X is set to 

129

 

Default, X is set to 

128

 

Default, X is set to 

255

 

The sensor continuously measures the amount of light 
reaching the sensor to determine if an object is picked 

up  (bright)  or  placed  back  (dark).  The  thresholds  levels 

for a pick-up or place-back can be adjusted using raw 
light values. For more information please see the manual 
calibration process on page 4.

When set to 4:1, the sensor will provide a trigger on pick-up 
and place-back of an object. When set to 4:2, the sensor 
will provide the Raw Light measurements. See page 2 for 
more information. 

When set to 4:3, the sensor will provide a trigger on pick-up 

and place-back of an object (see page 2). Furthermore, it 

will continuously auto-calibrate by automatically adjusting 

the sensor's sensitivity (setting 18) in such a way that in 

case of a place-back the raw light value is between 0-25 

(setting 14) and in case of a pick-up the raw light value is 
between  225-255  (setting  15).  For  example:  in  case  the 
raw light value is 255 (max), the sensor will automatically 

decrease the sensitivity until the light value will be just 
above 225. 

Activating auto-calibration can be a solution in cases 

where fluctuating light conditions cause unstable behavior 
of the sensor. However we recommend to always first try 

to create a stable application by manual calibration (see 

page 5) or adjusting the physical integration (see page 4 
and 5) of the sensor.

5

This  setting  specifies  the  number  of  samples  which  are 

averaged to determine the sensor's output. The higher the 
number of samples, the less responsive the sensor will be 
to change, but also the more stable in case of challenging 
environments. The lower the number of samples, the more 
responsive the sensor will be to change. Please note that 
typically this setting does not need to be adjusted.

X001S[6:1]

X001S[6:5]

X001S[6:9]

X001S[6:2]

X001S[6:6]

X001S[6:10]

X001S[6:3]

X001S[6:7]

X001S[6:11]

X001S[6:4]

X001S[6:8]

X001S[6:12]

Setting 6: Sample averaging (advanced)

1. No averaging

2. Running average of 2 samples (def)

3. Running average of 4 samples
4. Running average of 8 samples
5. Running average of 16 samples
6. Running average of 32 samples 
7. Running average of 64 samples
8. Running average of 128 samples
9. Running average of 256 samples
10. Running avg of 1024 samples
11. Running avg of 2048 samples 
12. Running avg of 4096 samples

0

50

Raw light value

dark

bright

100

150

200

255

place-back

pick-up

se

�.

 

10

se

�.

 

11

se

�.

 

12

se

�.

 

13

Содержание XZ Series

Страница 1: ...e without prior notice 1 Table of content 1 General 1 2 Product overview 1 3 Functionality and API commands 2 3 1 Pick up and place back detection 2 3 2 Raw light measurement 2 4 Installation requirements and guidelines 3 4 1 Connection Diagrams 3 4 2 Hardware integration guidelines 3 4 3 Manual calibration 4 5 Settings 5 5 1 Settings 5 6 Quick test 7 XZ L20 Pick up detection light measurement Man...

Страница 2: ... when the object is placed back less light will reach the sensor and an API command is triggered as well These API messages have the following format 3 2 Raw light measurement The XZ Light sensor can also indicate the amount of light reaching the sensor as a raw decimal value The raw decimal value is a unfiltered direct AD conversion of the light measurement circuit and will therefore fluctuate We...

Страница 3: ... the double sided tape on the bottom flat side of the sensor A common thickness for the top panel is 3 5mm The thicker the top panel the less light will be able to reach the sensor especially when the top panel is made out of dark light absorbing material In these cases we recommend to either make sure there is a light source directly perpendicular above the sensor or increase the diameter of the ...

Страница 4: ...nsor may need to be calibrated again Measure raw light values 1 Set the sensor to Raw light values via setting 4 The command to do so is X001S 4 2 2 Place the object on the sensor Write down the value of the incoming API command For example X001A 30 3 Pick up the object from the sensor Write down the value of the incoming API command For example X001A 120 In case both values are very low e g 0 and...

Страница 5: ... to 4 3 the sensor will provide a trigger on pick up and place back of an object see page 2 Furthermore it will continuously auto calibrate by automatically adjusting the sensor s sensitivity setting 18 in such a way that in case of a place back the raw light value is between 0 25 setting 14 and in case of a pick up the raw light value is between 225 255 setting 15 For example in case the raw ligh...

Страница 6: ...same light conditions Example if the output of a raw light measurement is 0 and X is increased to 150 the Raw light value will increase e g to 20 So the more sensitive the higher the raw light value will be in the same light conditions When the sensor is set the auto calibration setting 4 3 thesensorwillcontinuouslyauto calibratebyautomatically adjusting the sensor s sensitivity setting 18 This is...

Страница 7: ...ble Both the green status LED of the sensor and the status LED of the controller should blink Uncover the light sensor to trigger a pick up If the sensor is not yet installed behind a front panel you can rotate the sensor so that the bottom flat side is facing upwards and towards the light Both the green status LED of the sensor and the status LED of the controller should blink For a full test we ...

Отзывы: