1. General

The XZ Light sensor can detect the amount of light that reaches the sensor. Typically, this value is used to determine whether 
an object is picked-up from the sensor, or placed back. This document provides explanation of the available functionalities 
and instructions on how to install and integrate the sensor into your digital signage installation.

The information in this document is created for users who are familiar with the Nexmosphere API and are able to control a 
basic setup with a Nexmosphere API controller. If this is not the case yet, please read the general documentation on the 

Nexmosphere serial API first.

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

PRODUCT MANUAL

XZ RANGE  | LIGHT SENSOR

© 2021 Nexmosphere. All rights reserved. v1.0 / 08-21    

All content contained herein is subject to change without prior notice

Table of content

 

1. General 

 

 

 

 

 

 

 

 

 

                      1

 2. 

Product 

overview 

          1

 

3. Functionality and API commands

       

2

 

 

3.1 Pick-up and place-back detection 

2

 

 

3.2 Raw light measurement 

2

 

4. Installation requirements and guidelines

 

    

3

 

 

4.1 Connection Diagrams 

3

  

4.2 Hardware integration guidelines 

3

  4.3 

Manual 

calibration 

       

4

 

5. Settings

 

5

  

5.1 Settings 

5

 

6. Quick test

 

    

7

XZ-L20

Pick-up detection (light measurement)

Manual calibration controls

Auto calibration

The XZ Light sensor utilizes a Phototransistor which can measure the 
amount of light reaching the sensor. The phototransistor is located 

on the bottom (flat) side of the sensor.

Typically, the sensor is installed behind a cut-out of a top panel. 

On the top panel, objects are placed of which a pick-up or place-back 
needs to be detected. When a product is picked-up, light reaches 
the phototransistor. When a product is placed back, the cut-out is 
covered, blocking the light.

XZ-L20

2. Product overview

The XZ Light sensor is available in 1 model: 

XZ-L20

Top

Bottom

Phototransistor

top panel

top panel

Top view

Side view

cut-out

cut-out

Содержание XZ Series

Страница 1: ...e without prior notice 1 Table of content 1 General 1 2 Product overview 1 3 Functionality and API commands 2 3 1 Pick up and place back detection 2 3 2 Raw light measurement 2 4 Installation requirements and guidelines 3 4 1 Connection Diagrams 3 4 2 Hardware integration guidelines 3 4 3 Manual calibration 4 5 Settings 5 5 1 Settings 5 6 Quick test 7 XZ L20 Pick up detection light measurement Man...

Страница 2: ... when the object is placed back less light will reach the sensor and an API command is triggered as well These API messages have the following format 3 2 Raw light measurement The XZ Light sensor can also indicate the amount of light reaching the sensor as a raw decimal value The raw decimal value is a unfiltered direct AD conversion of the light measurement circuit and will therefore fluctuate We...

Страница 3: ... the double sided tape on the bottom flat side of the sensor A common thickness for the top panel is 3 5mm The thicker the top panel the less light will be able to reach the sensor especially when the top panel is made out of dark light absorbing material In these cases we recommend to either make sure there is a light source directly perpendicular above the sensor or increase the diameter of the ...

Страница 4: ...nsor may need to be calibrated again Measure raw light values 1 Set the sensor to Raw light values via setting 4 The command to do so is X001S 4 2 2 Place the object on the sensor Write down the value of the incoming API command For example X001A 30 3 Pick up the object from the sensor Write down the value of the incoming API command For example X001A 120 In case both values are very low e g 0 and...

Страница 5: ... to 4 3 the sensor will provide a trigger on pick up and place back of an object see page 2 Furthermore it will continuously auto calibrate by automatically adjusting the sensor s sensitivity setting 18 in such a way that in case of a place back the raw light value is between 0 25 setting 14 and in case of a pick up the raw light value is between 225 255 setting 15 For example in case the raw ligh...

Страница 6: ...same light conditions Example if the output of a raw light measurement is 0 and X is increased to 150 the Raw light value will increase e g to 20 So the more sensitive the higher the raw light value will be in the same light conditions When the sensor is set the auto calibration setting 4 3 thesensorwillcontinuouslyauto calibratebyautomatically adjusting the sensor s sensitivity setting 18 This is...

Страница 7: ...ble Both the green status LED of the sensor and the status LED of the controller should blink Uncover the light sensor to trigger a pick up If the sensor is not yet installed behind a front panel you can rotate the sensor so that the bottom flat side is facing upwards and towards the light Both the green status LED of the sensor and the status LED of the controller should blink For a full test we ...