PRODUCT MANUAL | XT-EF SERIES AIR GESTURE SENSOR
6
XM Controllers (XM-350 and XM-370)
All XM controllers are powered via 5V DC input to which
a grounded power supply can be connected.
Currently, Nexmosphere does not have grounded 5V
power supplies in it's product portfolio.
EM Modules (EM-2, EM-5 and EM-6)
Some EM modules have a DC power input to which a
grounded power supply can be connected.
EM-2 and EM-5
Currently, Nexmosphere does not have grounded 12V
power supplies in it's product portfolio.
EM-6
24V/1.67A grounded power supply EU:
PS-2416EU
24V/1.67A grounded power supply US:
PS-2416US
24V/3.75A grounded power supply EU:
PS-2438EU
24V/3.75A grounded power supply US:
PS-2438US
X-talk cable to
XT-EF sensor
5V grounded
power supply
X-talk cable to
XT-EF sensor
Grounded DC
Power supply
4.3 Hardware integration guidelines
Top panel material
The XT-EF Series sensor can be installed behind any non-metal top panel, creating a completely invisible solution. The
maximum recommended thickness for the
XT-EF30,
XT-EF630
and
XT-EF650
is 22mm for acrylic or glass, and 18mm for
wood. For these models, the material and thickness of the top panel will only have a minor affect (if any) on the detection
range and the performance in general.
The
XT-EF680
has a different technical design to create a large sensor surface and high detection range. Therefore the
XT-EF680 is more sensitive to the material and thickness of the applied top panel. There are 7 calibration profile settings
available for the XT-EF680 to optimize the performance for a specific type of top panel (see section 3.4, page 5). This enables
the sensor to be placed behind a thick surface such as 36mm of wood or 100mm of brick. Please note that the calibration
profiles for these thick surfaces are tuned to a situation in which the sensor is only attached to the surface and has free space
on the back. For example during a test situation, when placing the sensor on a table and then placing a 36mm wooden test
panel on top, the sensor might not perform optimal as the back of the sensor is not free, but placed on a table top.
EF sensor
Top panel