4 - Installation requirements and guidelines

When integrating an XT-EF Series sensor into your digital signage installation, several installation requirements and guidelines 
need to be taken into account in order for the sensor to perform optimal and operate stable.

4.1 Electrical installation requirements

Grounding

The XT-EF Series sensors transceives an electrical field and measures changes within that field. Based on these changes, it 
can detect AirButton and AirGesture input. In order for the electrical field to remain stable, the sensor needs to be grounded. 
This can be achieved via two main methods:
•  Use a grounded power supply to power the Xperience controller (to which the XT-EF sensor is connected. An overview 

of the connection options is provided in section 4.2

•  Connect the Xperience controller (to which the XT-EF sensor is connected), to a mediaplayer or PC which is grounded. 

Please note that most mediaplayers are not grounded.

Avoid proximity of floating ground planes

When the sensor is placed in close proximity to large floating ground planes, this can cause  interference of the electrical 
field of the XT-EF sensor which can result into unstable behaviour. A typical example would be a large monitor which is not 
grounded. Please note that when the Xperience controller is powered with a grounded power supply, this will also ground the 
connected mediaplayer/PC, which subsequently will also ground the connected monitor.

XN Controllers (XN-135, XN-165, XN-185,  XN-180)

All XN controllers are powered via USB. As USB power 
supplies  are  typically  not  grounded,  a  USB/DC  split 
cable is needed to which a grounded power supply can 
be connected.

4.2 Connection Diagrams

There are multiple options for grounding the different Xperience controllers using a grounded power supply:

XC Controllers (XC-700, XC-800 and XC-900 Series)

All XC controllers are powered via 12 or 24V DC input 
to which a grounded power supply can be connected.

24V/1.67A grounded power supply EU: 

PS-2416EU

24V/1.67A grounded power supply US: 

PS-2416US

24V/3.75A grounded power supply EU: 

PS-2438EU

24V/3.75A grounded power supply US: 

PS-2438US

5

Grounded DC

Power supply

XC

X-talk cable to 

XT-EF sensor

XN

5V grounded 

power supply

CA-UD5B

split cable USB/DC

X-talk cable to 

XT-EF sensor

Содержание XT-EF Series

Страница 1: ...50 and XT EF680 also offer AirGesture detection which includes detecting AirSwipes and AirWheels The detection range of the sensors varies with the size Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com PRODUCT MANUAL XT EF SERIES AIR GESTURE SENSOR 2020 Nexmosphere All rights reserved v1 0 11 20 All content contained herein is subject to change...

Страница 2: ...ge 9 The maximum range for AirButton detection is different for each XT EF sensor model Please see the overview on page 1 for more info AirButton detection can be disabled Please see section 3 4 Settings page 9 When an AirButton far or near is detected the sensor checks for a short period of time if an AirGesture is detected as well This avoids that both an AirButton and AirGesture API command is ...

Страница 3: ... for each XT EF sensor model Please see the overview on page 1 for more info AirSwipe detection can be disabled Please see section 3 4 Settings page 9 In order for a swipe gesture to be detected the hand movement needs to cover a least 70 of the sensor s length left right or width up down When an AirButton command is send while executing an AirSwipe consider increasing the AirButton delay setting ...

Страница 4: ...detected direction is counter clockwise The API output for AirWheel detection in absolute value mode is as follows X001B Wv XXX AirWheel value XXX 001 100 When implementing AirWheel triggers consider the following The amount of API triggers per full rotation can be adjusted Please see section 3 4 Settings page 9 When the absolute value has reached 100 max clockwise rotations will not result in new...

Страница 5: ...se note that most mediaplayers are not grounded Avoid proximity of floating ground planes When the sensor is placed in close proximity to large floating ground planes this can cause interference of the electrical field of the XT EF sensor which can result into unstable behaviour A typical example would be a large monitor which is not grounded Please note that when the Xperience controller is power...

Страница 6: ...erial The XT EF Series sensor can be installed behind any non metal top panel creating a completely invisible solution The maximum recommended thickness for the XT EF30 XT EF630 and XT EF650 is 22mm for acrylic or glass and 18mm for wood For these models the material and thickness of the top panel will only have a minor affect if any on the detection range and the performance in general The XT EF6...

Страница 7: ...egative effect on the detection range Please note that the XT EF sensor does work behind almost all other common types of glass whether it is with 1 glass panel or multiple 2020 Nexmosphere All rights reserved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com PRODU...

Страница 8: ...IES AIR GESTURE SENSOR 8 recommended positioning recommended height AirButton Any horizontal vertical or angled horizontal or angled below shoulder height vertical shoulder height AirSwipe left right Any horizontal vertical or angled horizontal or angled below shoulder height vertical any height AirSwipe up down Vertical or Angled vertical shoulder height angled below shoulder height AirWheel Any ...

Страница 9: ... detection range for AirButton NEAR detection So the lower the X value the higher the detection distance and vice versa Please note that the 1 100 range for AirButton NEAR has a different correlation to the absolute detection range then the 1 100 range for AirButton Far X is a value between 1 50 and it s default value is 10 It determines how far the hand needs to be placed above the AirButton FAR ...

Страница 10: ...ove the XT EF sensor electrode to the left or right Make sure your hand is placed well within the range of the sensor Both the white status LED of the XT EF driver and the status LED of the controller should blink once For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 5 For more information on how to setu...

Отзывы: