Light conditions

Make sure the environment in which the sensor is installed is well lit and that enough light is able to hit the face of the person 
in front of the camera. 

Light coming from an angle which reaches the person's face can cause a shadow on one side of the face which will  result into 
a decrease of the sensor's responsiveness and accuracy. Therefore please make sure that he light sources are evenly spread 
and that the face of the person in front of the sensor is evenly lit

© 2020 Nexmosphere. All rights reserved. v1.0 / 11-20  

All content contained herein is subject to change without prior notice

N ex m o s p h e re

Le   H av re   1 3 6
5 6 2 7   SW   E i n d h ove n   •   T h e   N e t h e r l a n d s

T

  + 3 1   4 0   2 4 0   7 0 7 0

E

  s u p p o r t @ n ex m o s p h e re.c o m

PRODUCT MANUAL | X-EYE GENDER SENSOR

5

XY-510 XY-520

Field of view Angle

90°

50°

Min. detection distance

15cm

35cm

Max. detection distance

120cm

250cm

Field of view angle and detection range

When installing the sensor, take the field of view angle into 

account to make sure the sensor can detect the people 
which are standing in front of it.

Panel cut out

The lens of the sensor needs to have a clear view of the person standing in front of it. All other parts of the X-Eye Gender 
sensor can be hidden behind a panel. In order to do so, a circular cut out for the lens needs to be made. The recommended 
diameter of the cut out in a 3mm panel is 

10mm

 for the 

XY-510

 and 

6.5mm

 for the 

XY-520

. For more information on the 

mechanical dimension please see the datasheet of the XY-510 and XY-520.

XY-510

detection field

top view

XY-520

detection field

top view

50°

90°

120cm

15cm

250cm

35cm

Содержание X-EYE XY-510

Страница 1: ...der sensors feature the same functionality and will detect the gender and estimate the age of the person in front of the sensor The detection range and field of view varies between the two models Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 2020 Nexmosphere All rights reserved v1 0 11 20 All content contai...

Страница 2: ...ng The sensor only detects one person at a time and will always analyze the person closest to the sensor The confidence level thresholds very low low and high can be adjusted Please see section 5 Settings page 7 Whether or not the sensor should send an API command when the confidence level on the detected gender is low can be adjusted Please see section 5 Settings page 7 P Person detection 0 No Pe...

Страница 3: ...n 5 Settings page 7 The sensor determines the gaze direction based on the position and angle of the person s jaw It does not take the eye direction into account When the gaze direction is unidentified this will be indicated with an U 2020 Nexmosphere All rights reserved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The ...

Страница 4: ...lk interface before powering the Xperience controller Otherwise the X Eye Gender sensor will not be recognized by the Xperience controller and no sensor output will be provided 4 XN this side up X Eye DC Power supply XC this side up X Eye 4 2 Hardware integration guidelines Orientation placement sensor Install the sensor in the orientation depicted in the illustration on the right In all other ori...

Страница 5: ...or t nexmosphere com PRODUCT MANUAL X EYE GENDER SENSOR 5 XY 510 XY 520 Field of view Angle 90 50 Min detection distance 15cm 35cm Max detection distance 120cm 250cm Field of view angle and detection range When installing the sensor take the field of view angle into account to make sure the sensor can detect the people which are standing in front of it Panel cut out The lens of the sensor needs to...

Страница 6: ...rved v1 0 11 20 All content contained herein is subject to change without prior notice Nexmosphere Le Havre 136 5627 SW Eindhoven The Netherlands T 31 40 240 7070 E suppor t nexmosphere com 6 PRODUCT MANUAL X EYE GENDER SENSOR 5 Settings The X Eye Gender sensor has multiple settings which determine the behaviour and output of the sensor The settings can be adjusted by sending X talk setting comman...

Страница 7: ...Whendisabling 1 thesensorwillnotsendanAPImessage when the detected Gender changes and the confidence level of the detected gender is low L Whendisabling 1 thesensorwillnotsendanAPImessage when the age estimation changes and the confidence level of the age estimation is low L Default the sensor does not send an API message when the detected gaze direction changes When enabling 1 the sensor will sen...

Страница 8: ...er up is completed will be lit continuously Step 2 Test detection Stand in front of the sensor with you face directed towards the sensor s lens The status LED of the controller should blink For a full test we recommend to connect the setup to a mediaplayer or PC and test all API commands listed in this document see section 3 page 2 3 For more information on how to setup a test for your controller ...

Отзывы: