background image

 

Beta

 

V1.00

 

07/01/2012

 

Page

 

|

 

9

  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Содержание IOP-1

Страница 1: ...Beta V1 00 07 01 2012 Page 1 Intelligent Interoperability Gateway FOR THE KENWOOD NX 700 AND NX 800 TRANSCIEVERS INSTRUCTION MANUAL ...

Страница 2: ...ES 3 INTRODUCTION 3 TYPICAL APPLICATIONS 4 PROGRAMMING THE RADIO 5 SCAN PROGRAMMING 12 INSTALLATION 13 RECORDING THE VOICE PROMPTS 16 SETTINGS MENU 17 JUMPER SETTING DESCRIPTION 18 GATEWAY OPERATION 20 TECHNICAL SUPPORT 23 FCC DECLARATION OF CONFORMITY 24 ...

Страница 3: ...rks by allowing a user to remotely access the repeater just by placing a regular telephone call to the NEXLINK gateway from any cell phone standard land line phone or internal PBX The NEXLINK gateway auto answers an incoming call At this point the user has full control over the connected Kenwood radio as if sitting in front of it Within seconds the user can instantly connect to digital or analog t...

Страница 4: ...Beta V1 00 07 01 2012 Page 4 TYPICAL APPLICATIONS ...

Страница 5: ... 01 2012 Page 5 PROGRAMMING THE RADIO There is required programming that must be completed in the radio using Kenwoods KPG 111D software before the NEXLINK will work The following screen captures show these settings ...

Страница 6: ...Beta V1 00 07 01 2012 Page 6 ...

Страница 7: ...Beta V1 00 07 01 2012 Page 7 ...

Страница 8: ...Beta V1 00 07 01 2012 Page 8 ...

Страница 9: ...Beta V1 00 07 01 2012 Page 9 ...

Страница 10: ...Beta V1 00 07 01 2012 Page 10 ...

Страница 11: ...nel one on zones 1 8 Therefore it is recommended that there only be one channel programmed as shown below for each zone It may be necessary to copy information to multiple zones so that you can add multiple users groups from the same zone Make sure that all other configurations that apply specifically to your system are programmed These include channel frequencies zone type signaling site informat...

Страница 12: ...n be a very important feature If the radio is programmed for scan see the screen capture from Kenwoods KPG 111d programming software below the user will have the ability to switch scanning on or off remotely See the DTMF command list in the Gateway Operation section of this instruction manual ...

Страница 13: ...to and from the repeater is perfect If the radio is to be located at the tower site then the appropriate measures should be taken to ensure a solid and balanced RF connection Before connecting the gateway to the radio make sure that all programmed zones in the radio have a clear transmit and receive path and the programmed ID s and zones are the desired user groups to be used with the gateway PLUG...

Страница 14: ...Beta V1 00 07 01 2012 Page 14 Supplied Plug N Play Cable Harness Description 3 Connections to 2 Connections to The NEXLINK Gateway The Radio ...

Страница 15: ...Beta V1 00 07 01 2012 Page 15 Connections Fig 1 ...

Страница 16: ...d see REC appear on the LCD screen of the radio If you see PA instead the radio is not programmed correctly Refer to the programming section 6 At this point you are ready to record the voice prompt for zone 1 channel 1 in the radio The radio will show on its LCD display the Zone you will be recording Hold the microphone about 2 inches from your mouth Press and hold the microphones PTT and speak th...

Страница 17: ... have 3 different functions 1 NUMBER OF RINGS TO ANSWER Press 1 then the desired number of rings The NexLink gateway can be programmed to answer after a set number of rings Press DTMF 1 then the number of rings you would like the gateway to auto answer the call 2 SET THE PASSCODE Press 2 The NexLink gateway is equipped with a 4 digit DTMF passcode feature in case an erroneous user calls the gatewa...

Страница 18: ... ports it beca eway will im phone com gateway to for this jump sharing mod wering devic will come on hang up allo d 7 01 2012 mpers on th and set asid he right The answer if rin he radio is m o is mixed w n put this jum er of rings to olume The f detect reve e phone com all hangs up ause if the u mediately d pany does n reset allow per is in or e de used whe ce After yo line You wi owing you to e ...

Страница 19: ...ble without entering a passcode This feature might be convenient if the unit is installed on an inside PBX analog telephone line where there would be limited personnel use 1 If this jumper is out the timeout timer mentioned in the Operation section of this manual is set to 4 minutes If the jumper is installed it will be set to 8 minutes The factory default is not installed or 4 minutes Reassembly ...

Страница 20: ...er in the radio is passed to the user on his phone to monitor Dispatch One activity If the radio connected to the gateway is progrmamed for scan and the user has turned it on the user will hear the prompt Scanning prior to the Zone prompt MONITORING THE CHANNEL The user will now be monitoring the last zone previously selected If the user just chooses to monitor the frequency after 4 or 8 minutes s...

Страница 21: ...or actice to use extended pe o the users left to spea 7 01 2012 button func Fig 2 he users DT or all zones switches zo est for the KEY 9 ateway to c microphone with the re ssed for any m the users icrophone o ighly recomm F without m ommended monitoring the microph riods The u transmissio ak If the use ctions from t TMF pad on The user w ones If there e unit will ommand th e The gatew epeater was ...

Страница 22: ...o key REQUESTING RADIO STATUS PRESS STAR THEN STAR At any time the user may request the status of the radio by pressing star then star The gateway will respond with Scanning if the radio is scanning then it will respond with the channel prompt for the current zone the radio is switched to CALL TERMINATION PRESS THEN THEN HANG UP It is very important that the user press the star key followed by the...

Страница 23: ...Beta V1 00 07 01 2012 Page 23 TECHNICAL SUPPORT Technical Support is available directly from onthegodevices Monday Friday 9 00am 5pm EST Please call 954 261 8968 for assistance ...

Страница 24: ...FCC DECLARATION OF CONFORMITY NEXLINK INTEROPERABILITY GATEWAY IOP 1 I the undersigned hereby declare that the equipment specified above conforms to FCC Part 15 Directive s and standards July 01 2012 Mr John Troy onthegodevices LLC ...

Отзывы: