NexLink IOP-1 Скачать руководство пользователя страница 20

 

Beta

 

V1.00

 

07/01/2012

 

Page

 

|

 

20

  

 

GATEWAY

 

OPERATION

 

 

Once

 

the

 

NEXLINK

 

gateway

 

is

 

properly

 

installed

 

and

  

the

 

radio

 

is

 

programmed

 

to

 

be

 

used

 

with

 

the

 

NEXLINK

 

gateway,

 

operation

 

is

 

as

 

follows:

 

 

ACCESSING

 

THE

 

GATEWAY

 

To

 

gain

 

access

 

to

 

the

 

gateway,

 

the

 

user

 

simply

 

dials

 

the

 

telephone

 

number

 

connected

 

to

 

the

 

TELCO

 

port

 

on

 

the

 

gateway

 

from

 

a

 

cellphone

 

or

 

any

 

other

 

phone(which

 

usually

 

has

 

a

 

memory

 

stored

 

in

 

the

 

phone

 

for

 

the

 

gateway

 

telephone

 

number).

 

The

 

gateway

 

could

 

also

 

be

 

connected

 

to

 

a

 

PBX

 

system.

 

In

 

that

 

case,

 

the

 

user

 

would

 

enter

 

the

 

internal

 

extention

 

number.

 

The

 

NEXLINK

 

gateway

 

will

 

auto

answer

 

the

 

call

 

and

 

ask

 

the

 

user

 

for

 

a

 

4

 

digit

 

passcode(the

 

passcode

 

entry

 

can

 

be

 

disabled,

 

see

 

the

 

“JUMPER

 

SETTING

 

DESCRIPTION,

 

jumper

 

2”

 

section

 

of

 

this

 

manual).

 

After

 

sucessful

 

entry,

 

the

 

gateway

 

will

 

respond

 

“NEXLINK

 

Ready”,

 

followed

 

by

 

the

 

prerecorded

 

voice

 

prompt

 

for

 

the

 

current

 

zone

 

that

 

the

 

radio

 

is

 

switched

 

to

 

such

 

as

 

“Dispatch

 

One”.

 

Immediately

 

audio

 

from

 

the

 

receiver

 

in

 

the

 

radio

 

is

 

passed

 

to

 

the

 

user

 

on

 

his

 

phone

 

to

 

monitor

 

“Dispatch

 

One”

 

activity.

 

If

 

the

 

radio

 

connected

 

to

 

the

 

gateway

 

is

 

progrmamed

 

for

 

scan,

 

and

 

the

 

user

 

has

 

turned

 

it

 

on,

 

the

 

user

 

will

 

hear

 

the

 

prompt

 

“Scanning”

 

prior

 

to

 

the

 

Zone

 

prompt.

 

 

MONITORING

 

THE

 

CHANNEL

 

The

 

user

 

will

 

now

 

be

 

monitoring

 

the

 

last

 

zone

 

previously

 

selected.

 

If

 

the

 

user

 

just

 

chooses

 

to

 

monitor

 

the

 

frequency,

 

after

 

4(or

 

8

 

minutes,

 

see

 

the

 

“JUMPER

 

SETTING

 

DESCRIPTION,

 

jumper

 

1)

 

minutes

 

the

 

user

 

will

 

be

 

asked

 

“Are

 

you

 

still

 

there?”

 

to

 

see

 

if

 

the

 

user

 

is

 

still

 

actively

 

using

 

the

 

gateway(the

 

gateway

 

is

 

checking

 

for

 

a

 

possible

 

dropped

 

call).

 

The

 

user

 

must

 

respond

 

by

 

pressing

 

“0”

 

or

 

any

 

other

 

key

 

to

 

reset

 

the

 

activity

 

timer.

 

If

 

the

 

user

 

does

 

not

 

respond

 

within

 

one

 

more

 

minute,

 

the

 

gateway

 

will

 

end

 

the

 

call.

 

The

 

gateway

 

will

 

never

 

interrupt

 

the

 

user

 

with

 

“Are

 

you

 

still

 

there”

 

if

 

the

 

user

 

is

 

active

 

in

 

a

 

conversation

 

that

 

has

 

transmissions

 

less

 

than

 

4(or

 

8)

 

minutes.

 

The

 

user

 

will

 

only

 

be

 

asked

 

if

 

the

 

user

 

shows

 

no

 

sign

 

of

 

activity.

 

It

 

is

 

reccommened

 

that

 

if

 

the

 

user

 

is

  

monitoring

 

for

 

extended

 

periods

 

of

 

time

 

that

 

the

 

user

 

mute

 

the

 

microphone

 

on

 

the

 

users’

 

phone

 

to

 

maintain

 

audio

 

in

 

one

 

direction.

 

 

 

Содержание IOP-1

Страница 1: ...Beta V1 00 07 01 2012 Page 1 Intelligent Interoperability Gateway FOR THE KENWOOD NX 700 AND NX 800 TRANSCIEVERS INSTRUCTION MANUAL ...

Страница 2: ...ES 3 INTRODUCTION 3 TYPICAL APPLICATIONS 4 PROGRAMMING THE RADIO 5 SCAN PROGRAMMING 12 INSTALLATION 13 RECORDING THE VOICE PROMPTS 16 SETTINGS MENU 17 JUMPER SETTING DESCRIPTION 18 GATEWAY OPERATION 20 TECHNICAL SUPPORT 23 FCC DECLARATION OF CONFORMITY 24 ...

Страница 3: ...rks by allowing a user to remotely access the repeater just by placing a regular telephone call to the NEXLINK gateway from any cell phone standard land line phone or internal PBX The NEXLINK gateway auto answers an incoming call At this point the user has full control over the connected Kenwood radio as if sitting in front of it Within seconds the user can instantly connect to digital or analog t...

Страница 4: ...Beta V1 00 07 01 2012 Page 4 TYPICAL APPLICATIONS ...

Страница 5: ... 01 2012 Page 5 PROGRAMMING THE RADIO There is required programming that must be completed in the radio using Kenwoods KPG 111D software before the NEXLINK will work The following screen captures show these settings ...

Страница 6: ...Beta V1 00 07 01 2012 Page 6 ...

Страница 7: ...Beta V1 00 07 01 2012 Page 7 ...

Страница 8: ...Beta V1 00 07 01 2012 Page 8 ...

Страница 9: ...Beta V1 00 07 01 2012 Page 9 ...

Страница 10: ...Beta V1 00 07 01 2012 Page 10 ...

Страница 11: ...nel one on zones 1 8 Therefore it is recommended that there only be one channel programmed as shown below for each zone It may be necessary to copy information to multiple zones so that you can add multiple users groups from the same zone Make sure that all other configurations that apply specifically to your system are programmed These include channel frequencies zone type signaling site informat...

Страница 12: ...n be a very important feature If the radio is programmed for scan see the screen capture from Kenwoods KPG 111d programming software below the user will have the ability to switch scanning on or off remotely See the DTMF command list in the Gateway Operation section of this instruction manual ...

Страница 13: ...to and from the repeater is perfect If the radio is to be located at the tower site then the appropriate measures should be taken to ensure a solid and balanced RF connection Before connecting the gateway to the radio make sure that all programmed zones in the radio have a clear transmit and receive path and the programmed ID s and zones are the desired user groups to be used with the gateway PLUG...

Страница 14: ...Beta V1 00 07 01 2012 Page 14 Supplied Plug N Play Cable Harness Description 3 Connections to 2 Connections to The NEXLINK Gateway The Radio ...

Страница 15: ...Beta V1 00 07 01 2012 Page 15 Connections Fig 1 ...

Страница 16: ...d see REC appear on the LCD screen of the radio If you see PA instead the radio is not programmed correctly Refer to the programming section 6 At this point you are ready to record the voice prompt for zone 1 channel 1 in the radio The radio will show on its LCD display the Zone you will be recording Hold the microphone about 2 inches from your mouth Press and hold the microphones PTT and speak th...

Страница 17: ... have 3 different functions 1 NUMBER OF RINGS TO ANSWER Press 1 then the desired number of rings The NexLink gateway can be programmed to answer after a set number of rings Press DTMF 1 then the number of rings you would like the gateway to auto answer the call 2 SET THE PASSCODE Press 2 The NexLink gateway is equipped with a 4 digit DTMF passcode feature in case an erroneous user calls the gatewa...

Страница 18: ... ports it beca eway will im phone com gateway to for this jump sharing mod wering devic will come on hang up allo d 7 01 2012 mpers on th and set asid he right The answer if rin he radio is m o is mixed w n put this jum er of rings to olume The f detect reve e phone com all hangs up ause if the u mediately d pany does n reset allow per is in or e de used whe ce After yo line You wi owing you to e ...

Страница 19: ...ble without entering a passcode This feature might be convenient if the unit is installed on an inside PBX analog telephone line where there would be limited personnel use 1 If this jumper is out the timeout timer mentioned in the Operation section of this manual is set to 4 minutes If the jumper is installed it will be set to 8 minutes The factory default is not installed or 4 minutes Reassembly ...

Страница 20: ...er in the radio is passed to the user on his phone to monitor Dispatch One activity If the radio connected to the gateway is progrmamed for scan and the user has turned it on the user will hear the prompt Scanning prior to the Zone prompt MONITORING THE CHANNEL The user will now be monitoring the last zone previously selected If the user just chooses to monitor the frequency after 4 or 8 minutes s...

Страница 21: ...or actice to use extended pe o the users left to spea 7 01 2012 button func Fig 2 he users DT or all zones switches zo est for the KEY 9 ateway to c microphone with the re ssed for any m the users icrophone o ighly recomm F without m ommended monitoring the microph riods The u transmissio ak If the use ctions from t TMF pad on The user w ones If there e unit will ommand th e The gatew epeater was ...

Страница 22: ...o key REQUESTING RADIO STATUS PRESS STAR THEN STAR At any time the user may request the status of the radio by pressing star then star The gateway will respond with Scanning if the radio is scanning then it will respond with the channel prompt for the current zone the radio is switched to CALL TERMINATION PRESS THEN THEN HANG UP It is very important that the user press the star key followed by the...

Страница 23: ...Beta V1 00 07 01 2012 Page 23 TECHNICAL SUPPORT Technical Support is available directly from onthegodevices Monday Friday 9 00am 5pm EST Please call 954 261 8968 for assistance ...

Страница 24: ...FCC DECLARATION OF CONFORMITY NEXLINK INTEROPERABILITY GATEWAY IOP 1 I the undersigned hereby declare that the equipment specified above conforms to FCC Part 15 Directive s and standards July 01 2012 Mr John Troy onthegodevices LLC ...

Отзывы: