BURNER INSTALLATION / PILOT CLEANING
BURNER INSTALLATION
Install the burner assembly by reversing the four (4) steps used for disassembly
making certain the burner assembly stands centered when complete.
After reassembly, the heater should be test fired. Observe the burner flame. The
flame should be blue with a slight yellow tipping.
PILOT CLEANING:
The pilot burner provides a flame to light the main burner. It also heats a
thermocouple which must be hot before allowing the main burner to come on.
If the pilot is blocked by debris, spider webs, etc., the pilot flame may be small and
the thermocouple may not heat up enough for the main burner to come on. If this
occurs it will be necessary to clean the pilot.
BEWARE
OF SPIDERS
CAUTION : BURNER TUBES MUST BE
INSPECTED AND CLEANED BEFORE FIRST
USE
Spiders and small insects occasionally spin webs or
make nests in the burner tubes and orifices during
warehousing and transit. These webs or nests can
lead to a gas flow obstruction which could result in
a fire on or around the burner tubes. This type of
fire is known as FLASH BACK and can cause
serious damage to your patio heater and create an
unsafe operating condition for the user. Although an
obstructed burner tube is not the only cause of
FLASH BACK it is the most common cause and
frequent inspections and cleaning of the burner
tubes is necessary .
Safety Valve
Cylinder
Lower Cone
Cylinder
17
Содержание 920-0010