European Gas Pressures and Specifications
Nexgrill Industries, Inc.
14050 Laurelwood PlChino, CA 91710 USA
0063CS7826
ID: 2531-18
Model
720-0882BF
Appliance Category
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(37)
I
3B/P(50)
Type of Gas
Butane
Propane
Butane, Propane or their mixture
Gas Pressure (mbar)
28-30
37
30
37
50
Main Burner Injector Size (Ø mm)
0.80
0.80
0.76
0.70
Searing Side Burner Injector Size (Ø mm)
1.02
1.02
0.94
0.84
Nominal Heat Input (Hs) (kW)
Main Burner (Total) + Searing Side Burner: 17.60
Gas Consumption (g/h)
Butane - Main Burner (Total) + Searing Side Burner: 1281
Propane - Main Burner (Total) + Searing Side Burner: 1258
NOTE:
Use 30 mbar regulator and its corresponding injector size for butane/propane under the category I3B/P(30).
Use 30 mbar regulator and its corresponding injector size for butane under the category I3+(28-30/37).
Use 37 mbar regulator and its corresponding injector size for propane under the category I3+(28-30/37).
Use 50 mbar regulator and its corresponding injector size for butane/propane under the category I3B/P(50).
Marking on the injector indicate the injector size. For example, "0.80" means the injector size is 0.80 mm.
Country
Gas Type
Pressure
BE, FR, IT, LU, IE, GB, GR, PT, ES, CZ, CH, SI
I3+
28-30/37 mbar
BG, CY, CZ, DK, EE, FI, HU, IS, LT, LV, MT, IT, NL, NO, RO, SK, SE, SI
I3B/P
30 mbar
PL
I3P
37 mbar
AT, CH, CZ, DE
I3B/P
50 mbar
8