11
8. Liquid
Propane
Hook-Up
Attach the regulator to the propane cylinder by
turning the regulator handle clockwise as shown in
Fig. 13. If the outdoor cooking appliance is not in use,
the gas must be turned “OFF” at the Liquid Propane
cylinder.
Check all gas supply fittings for leaks before
each use. Do not use the grill until all
connections have been checked and do not leak
(see “Leak Testing” instructions on page 12).
INSTALLATION INSTRUCTIONS
GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be specified by the grill manufacturer.
This grill is configured for Liquid Propane. Do not use a Natural Gas supply.
Total gas consumption (per hour) with all burners set on “HI”:
Main burners
44,000 BTU/Hr.
Rear burner
13,000 BTU/Hr.
Sear Side burner 15,000 BTU/Hr.
Total
72,000 BTU/Hr.
The installation of this appliance must conform with local codes or, in the absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA B149.2.
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for gas
burning appliances and equipment) and local codes.
LIQUID PROPANE CYLINDER REQUIREMENTS
(20-lb. Cylinder)
A dented or rusty Liquid Propane cylinder may be hazardous and should be checked by your supplier. Never
use a cylinder with a damaged valve. The Liquid Propane cylinder must be constructed and marked in
accordance with the specifications for Liquid Propane cylinders by the United States Department of
Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods Commission.
The 20-lb. cylinder must have a shut off valve terminating in a valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapor withdrawal.
The cylinder must include a collar to protect the cylinder valve.
Manifold pressure: (operating) 10 inches water column (W.C.), (non-operating) 11.2 inches water column (W.C.).
The Liquid Propane cylinder must be fitted with an Overfill Protection Device (OPD).
Remove the plastic valve cover from the Liquid Propane cylinder. Make sure the grill gas hoses do not contact
the grease pan or grill firebox when the Liquid Propane cylinder is placed into the cart.
Fig. 13