![Nexgrill 720-0371-LP Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/nexgrill/720-0371-lp/720-0371-lp_assembly-and-operating-instructions_1681725017.webp)
GAS HOOK UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. The grill
manufacturer must specify any replacement pressure
regulator and hose assembly.
This is a liquid propane configured grill. Do not attempt
to use a natural gas supply unless the grill has been
reconfigured for natural gas use.
Main burners
12,000 Btu/hr.
Side burner
12,000 Btu/hr.
Total
48,000 Btu/hr.
The installation of this appliance must conform with local
codes or, in the absence of local codes, to the national fuel
gas code, ANSI Z223. Installation in Canada must be in
accordance with the Standard CAN/CSA-b149.1 and/or .2
(installation code for gas burning appliances and
equipment) and local codes.
L.P. Tank Requirements:
A dented or rusty L.P. tank may be hazardous and
should be checked by your L.P. supplier. Never use a
cylinder with a damaged valve. The L.P. gas cylinder
must be constructed and marked in accordance with the
specifications for L.P. gas cylinders of the U.S.
Department of Transportation (DOT), or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission.
The cylinder must be provided with a shut valve
terminating in an L.P. gas supply cylinder valve outlet
specified, as applicable, for connection type QCC1 in
the standard for compressed gas cylinder valve outlet
and inlet connection ANSI/CGA-V-1.
The cylinder supply system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect
the cylinder valve.
Manifold pressure: (operating): 10” water column
(W.C.), (non-operating): 11.2” water column (W.C.).
L.P. GAS HOOK-UP:
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does not
come into contact with the grease tray or the grill
head.
CONNECTION:
Your grill is equipped with gas supply orifices for use
only with liquid propane gas. It is also equipped with a
high capacity hose/regulator assembly for connection
to a standard 20lb. L.P. cylinder (18-1/4” high, 12-1/4”
diameter).
To connect the L.P. gas supply cylinder, please follow
the steps below:
1. Make sure tank valve is in its full off position (turn
clockwise to stop)
2. Check tank valve to assure it has proper external
male threads (type 1 connection per ANSIZ21.81)
3. Make sure all burner valves are in their off
position.
4. Inspect valve connections, port, and regulator
assembly. Look for any damage or debris.
Remove any debris. Inspect hose for damage.
Never attempt to use damaged or obstructed
equipment. See your local L.P. gas dealer for
repair.
5. When connecting regulator assembly to the valve,
hand tightens the nut clockwise to a complete
stop. Do not use a wrench to tighten. Use of a
wrench may damage the quick coupling nut and
result in a hazardous condition.
6. Open the tank valve fully (counterclockwise). Use
a soapy water solution to check all connections
for leaks before attempting to light the grill, see
below. If a leak is found, turn the tank valve off
and do not use the grill until a local L.P. gas dealer
can make repairs.
To disconnect L.P. gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to
stop).
3. Detach the regulator assembly from the tank
valve by turning the quick coupling nut
counterclockwise.
I15Y06P-1
16
Содержание 720-0371-LP
Страница 22: ...GRILL LIGHTING INSTRUCTIONS I15Y06P 1 21 ...