Zigbee DALI TW Converter with power supply
■
If the actuator is operated without a gateway, connect the actuator to a transmitter via
Touchlink within 5 minutes after switching on the mains voltage.
A more detailed configuration can only be carried out with the NEXENTRO Config App.
DANGER!
Mortal danger of electric shock.
The following work must - unlike commissioning with App -be carried out under
mains voltage and therefore may only be carried out by an electrician!
Only use insulated tools for the work! Cover up live parts in the working environ-
ment.
Setting the minimum brightness
■
Press the Prog. button for longer than 4 seconds and release it.
The LED lights up green.
■
Press and hold the Prog. button for longer than 1 second.
The light switches to the lowest brightness and slowly becomes brighter. The LED flashes
green.
■
Once the desired brightness is reached, release the button Prog..
The current brightness is adopted as the minimum brightness and the LED lights up
green.
Press the Prog. button for less than 1 second or wait 30 seconds to return to normal oper-
ation.
9
Reset device
Deleting assignment to the Zigbee network and Bluetooth coupling
■
Switch off the supply voltage to the device four times in quick succession and switch it on
again. The pause between switching operations must be less than two seconds.
The actuator acknowledges the deletion of the network assignment and the Bluetooth
coupling to mobile end devices by flashing the light twice.
Restoring the device to factory settings
The device deletes the assignment to a network and all connections to Zigbee devices. Alternat-
ively, the device can also be reset with the NEXENTRO Config App.
DANGER!
Mortal danger of electric shock.
The following work must be carried out under mains voltage and therefore may only
be carried out by an electrician!
Only use insulated tools for the work! Cover up live parts in the working environ-
ment.
Precondition: Load is switched off.
■
Press the Prog. button (6) for longer than 20 seconds.
After approx. 20 seconds, the LED flashes rapidly alternately red and green.
■
Within 10 seconds, release the button and actuate it briefly once again.
The LED flashes more slowly alternately red and green, the device is reset to the default
settings and is restarted.
6 / 8
82403710
17.11.2021