FORM NO. L-20179-J-0814
5
INSTALLATION
MOUNTED ON THE SHAFT END OF A MOTOR
Refer to Figure 1.
1. Insert the customer supplied key into the motor shaft
keyway.
2. Slide the FMCB onto the motor shaft, then secure it
to the motor using customer supplied socket head
cap screws and lock washers.
3. Tighten the Set Screw.
Note
On Models 130-19 and 130-24, the Set Screw is Item
27. On all other models, the Set Screw is Item 35.
4. Install the Housing Guard over the open areas of the
FMCB and secure it using the fasteners provided with
the Housing Guard.
Refer to Figure 2.
1. Insert the Key (Item 25 or 33) into the output shaft of
the FMCB.
Note
On Models 130-19 and 130-24, the Key is Item 25.
On all other models, the Key is Item 33.
2. Slide the FMCB output shaft into the gear reducer.
3. Secure the FMCB to the gear reducer using customer
supplied socket head cap screws, lock washers, and
nuts.
4. Insert the customer supplied key into the motor shaft
keyway.
5. Slide the motor into the FMCB and secure it to the
FMCB using customer supplied socket head cap
screws, lock washers, and nuts.
6. Tighten the Set Screw.
Note
On Models 130-19 and 130-24, the Set Screw is Item
27. On all other models, the Set Screw is Item 35.
7. Install the Housing Guard over the open areas of the
FMCB and secure it using the fasteners provided with
the Housing Guard.
MOUNTED BETWEEN A GEAR REDUCER AND
A MOTOR
Figure 1
Motor
Customer
supplied Key
Set Screw
(Item 27 or 35)
Customer supplied socket
head cap screw and lock
washer
Housing
Guard
FMCB
Figure 2
Customer supplied socket
head cap screw, lock washer,
and nut
Motor
Customer
supplied key
Set Screw (Item
27 or 35)
Key (Item 25 or 33)
Customer supplied socket
head cap screw, lock
washer, and nut
Gear
Reducer
Housing
Guard
FMCB