Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.
36
NCi-311/NCi-311-R User Manual
Chapter 2: Camera Configuration
Auto Exposure Configuration
Maximum Exposure Time
Specifies the maximum exposure time when operating in Auto Exposure
mode, the range is 1/7 ~ 1/1000, with 1/1000 being the shortest exposure
length.
Maximum Sens Up Gain
Specifies the maximum gain when operating in Auto Exposure mode, the
range is 1 ~ 512, with 1 being the lowest gain.
Gamma Control
Default
Activates the default gamma state.
Gamma
Adjusts the gamma manually, the range is 0.01 ~ 1.00, with 0.01 being the
lowest value.