Before you start:
Please read the
instructions. Planning your installation
will save you time and effort.
Prior to installation, ensure that the local
distribution conditions (nature of the gas
and gas pressure) and the adjustment of
the appliance are compatible. The adjust-
ment conditions are stated on the data
badge.
This appliance is not connected to a combus-
tion evacuation device.
It shall be
installed and connected in accordance
with current installation regulation.
Particular attention shall be given to the
relevant requirements regarding ventila-
tion.
In your own interest and that of safety, it
is the law that all gas appliances be
installed and serviced by competent per-
sons. CORGI registered installers under-
take to work to satisfactory standards.
Where regulations or standards have
been revised since this handbook was
printed, always use the latest edition.
In the UK the regulations and stan-
dards are as follows:
1. Gas Safety Regulations (Installation
and Use).
2. Building Regulations - Issued by the
Department of the Environment.
3. Building
Standards
(Scotland)
(Consolidated) - Issued by the
Scottish Development Department.
4. The current I.E.E. Wiring Regulations.
5. Electricity at Work Regulations.
6. BS 6172 Installation of Domestic Gas
cooking Appliances
7. Installation & Servicing Instructions
for this appliance.
For installation in countries other than the
UK, the appliance must be connected in
accordance with all local gas and electrical
regulations.
In the Republic of Ireland, Installers
should refer to IS813 Domestic Gas
Installations.
Ventilation Requirements
The room containing the appliance should
have an air supply in accordance with
BS 5440: Part 2
• All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well.
• For room volumes up to 5m
3
an air
vent of 100cm
2
is required.
• If the room has a door that opens
directly to the outside, or the room
exceeds 10m
3
, NO AIR VENT is
required.
• For room volumes between 5m
3
and
10m
3
an air vent of 50cm
2
is required.
• If there are other fuel burning appli-
ances in the same room, BS 5440:
Part 2: 1989 should be consulted to
determine the air vent requirements.
• This appliance must not be installed
in a bed sitting room of less than
20m
3
or in a bathroom or shower
room.
Windows and permanent vents should
therefore not be blocked or removed with-
out first consulting a CORGI gas installer.
In the Republic of Ireland, refer to rele-
vant Irish Standards for correct ventila-
tion.
Failure to install appliances correctly
is dangerous and could lead to pros-
ecution.
18
INSTALLATION INSTRUCTIONS