NTSecureGateway
14 / 14
User Manual
11648_0008_0012_UM-User_Manual
Revision: DV A1
NewTec GmbH · Buchenweg 3 · 89284 Pfaffenhofen a.d. Roth · Germany · Tel.: +49 7302 9611-0 · [email protected] · www.newtec.de
F9
05
Installation
Installation Requirements
The NTSecureGateway is designed to be mounted in an electric cabinet with a minimum protection class of
IP54. It is intended to be mounted on a DIN Rail according to EN 60715 (35mm x 7.5mm). First snap in the
orange clip at the top position (1) to the DIN Rail. Then pull down the orange clip at the bottom side (2) with a
screw driver, to also snap it to the DIN Rail. Ensure that both orange clips are in the default position and the
housing is mounted firmly on the DIN Rail.
Figure 5: DIN Rail mounting
Initial commissioning
For initial commissioning connect 24 V to the power supply connector. The following connector is needed:
Phoenix Contact, Part No: 1836079.
Ensure that the supply voltage is not exceeding the values defined in
Table 1: Maximum Ratings, otherwise the device could be damaged.
Respect polarity, otherwise the device could be damaged.