Physical Description
User Manual for AZ430 WAN Satellite Modem
Figure 8 - Contact Closure Alarm Connections
Pin 2 and 4 are either floating or tied to chassis earthing.
10.0 MHz Reference Input
This input is used when you need a reference with enhanced stability or when you
need several devices to be synchronised to the same clock source. The level
should be 0 dBm nominally. The 10.0 MHz reference input will only be available if
this option is installed.
Ethernet Connection
A standard RJ-45 connector provides connection to an Ethernet hub in a LAN
(10/100BaseT). You can set the IP address and subnet mask from the front panel.
The default IP address is: 10.0.0.1.
You can send RMCP (Remote Monitoring and Control Protocol) commands to the
modem using the Ethernet interface. The commands are sent as data in a TCP/IP
stream. The used socket number is 5933. The RMCP protocol is exactly the same
as for the serial interface, with one small exception: the receiving device ignores
the RMCP address of the device (that is present in an RMCP command).
•
All RMCP commands are explained in the reference
manual of the AZ430 modem.
•
A separate general RMCP manual can be obtained via
. This manual explains how
Newtec devices can be remotely monitored and controlled
via the serial port or via Ethernet.
version 1.0
9
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS