![Newport Pt16 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/newport/pt16/pt16_operators-manual_1679965062.webp)
PLATINUM Series Controllers User’s Guide
62
Reference Section: Operating Mode (oPER)
8.
Reference Section: Operating Mode (oPER)
Operating Mode is used to activate the unit’s monitoring and controlling functions. It also allows
shortcut access to the Setpoint parameters while still running. Use Operating Mode to set the following
parameters and perform the following functions:
8.1
Normal Run Mode (oPER > RUN)
Select Normal Run Mode (RUN). The ENTER button starts the unit operating according to the
current input, output, and communications settings. Run Mode will automatically be entered
and activated at unit power-on if the Power on Confirmation (
) parameter is set to dSbL. The process value is displayed in the main
display, and if the unit uses dual displays, the current Setpoint value is displayed in the
secondary display. With the unit remaining active, the oPER menu selections can be navigated
to using the LEFT and RIGHT buttons.
8.2
Change Setpoint 1 (oPER > SP1)
Select the Change Setpoint 1 (SP1) parameter. This function allows Setpoint 1 to be changed
while remaining in Run Mode. Pressing the ENTER button after changing a Setpoint while in
RUN Mode returns to RUN Mode with no interruption in monitoring, control, or
communications operations. If remote Setpoint is enabled, Setpoint 1 cannot be changed
here and the display will flash.
Set the desired value for Setpoint 1. When changing the Setpoints from the operating mode
menu, the left arrow decreases the value with acceleration and the right arrow increases the
value with acceleration. This is different from the decimal place switching numeric change
control in other places as changes made here are usually limited.
Confirm the value.