Newport NPC DIG Series Скачать руководство пользователя страница 9

 

 

9

 

 

RISK OF ELECTRIC SHOCK! Indicates that a risk of electric shock is present and the 
associated warning should be observed.   

 

CAUTION! REFER TO OPERATOR´S MANUAL 

– Refer to your operator’s manual for 

additional information, such as important operating and maintenance instructions. 

 

RISK OF ELECTRIC SHOCK!

 

 

 

Do not open the units! There are no user serviceable parts inside and opening or removing 
covers  may  expose  you  to  dangerous  shock  hazards  or  other  risks.  Refer  all  servicing  to 
qualified service personnel. 

 

Do not spill any liquids into the cabinet or use the units near water. 

 

CAUTION

!  

 

 

Allow  adequate  ventilation  around  the  units  so  that  heat  can  properly  dissipate.  Do  not 
block ventilated openings or place the units near a radiator, oven, or other heat sources. Do 
not  put  anything  on  top  of  the  units  except  those  that  are  designed  for  that  purpose  (e.g. 
actuators). 

 

Only work with the units in a clean and dry environment! Only specially prepared units (e.g. 
actuators) can work under other conditions! 

 

Please only use original parts from 

Newport Corporation

Newport Corporation

 does not 

give  any  warranty  for  damages  or  malfunction  caused  by  additional  parts  not  supplied  by 

Newport  Corporation

.  Additional  cables  or  connectors  will  change  the  calibration  and 

other specified data. This can change the specified properties of the units and cause them 
to malfunction. 

 

Piezo elements are sensitive systems capable of the highest positioning accuracy. They will 
demonstrate their excellent properties only if they are handled correctly! Please mount them 
properly at the special mounting points. 

 

Immediately  unplug  your  unit  from  the  wall  outlet  and  refer  servicing  to  qualified  service 
personnel under the following conditions: 

 

 

when the cords or plugs are damaged 

 

if liquid has been spilled or objects have fallen into the unit 

 

if the unit has been exposed to rain or water 

 

if the unit has been dropped or the housing is damaged 

Содержание NPC DIG Series

Страница 1: ...n Manual Digital Piezo Amplifier Series NPCxxxDIG Models NPC50DIG NPC300DIG Please read carefully before switching on the power Please see safety instructions for using piezoelectric actuators and pow...

Страница 2: ...www newport com 2 English version last change 2017 02 16 by TP...

Страница 3: ...3...

Страница 4: ...for checking the function of the system quick start 11 8 How to operate the digital amplifier series NPCxxxDIG 12 8 1 Common Introduction 12 8 2 User Elements Connections 12 8 2 1 Front Panel 12 8 2...

Страница 5: ...rporation You will also find additional information regarding piezoelectric products Definition All systems from Newport Corporation such as electronics actuators and optical systems are called units...

Страница 6: ...uction and form put by us into circulation is in accordance with all relevant essential requirements of the EMC Directive 2014 30 EU This declaration is no longer valid if the device is modified witho...

Страница 7: ...l occur After excitation of the actuators by a voltage in the upper control range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will o...

Страница 8: ...regular waste Instead it is the user responsibility to dispose of waste equipment according to the local laws The separate collection and recycling of the waste equipment at the time of disposal will...

Страница 9: ...rs Only work with the units in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please only use original parts from Newport Corporation Newport C...

Страница 10: ...cables e g power cords sensor cables actuator cables optical cables Do not block ventilated openings or place the units near a radiator oven or other heat sources Plug in the power cord completely so...

Страница 11: ...r shape should be parallel each to each other and not have any scratches If there is any damage to the system please contact our local representative immediately If the packaging material is damaged p...

Страница 12: ...high speed positioning with the highest accuracy available It includes rise time optimization and an active oscillation damping for every special application The NPCxxxDIG comes with an auto calibrati...

Страница 13: ...13 8 2 2 Back Panel...

Страница 14: ...www newport com 14 8 3 Function The following sketch shows the function groups of the amplifier sketch 1 function groups of the amplifier...

Страница 15: ...akes for the output to get a certain value For a step input it is the time taken for the output to equal the input yi yi ki err Ts Ts 1 sample frequency 50 kHz 1 ki time constant yi output of i term I...

Страница 16: ...er of magnitude While using open loop you can also switch on the notch filter to reduce stimulation of the resonant frequency Using the notch filter might increase noise The PID specific parameters kp...

Страница 17: ...500Hz Actuator measurement connector PIEZO 15pin D Sub plug Monitor output 0 10V programmable signal source Monitor output impedance 1k Modulation input 0 10V disconnectable Modulation input impedanc...

Страница 18: ...ription value monsrc value monitor output default 0 0 position value in closed loop 1 reference input 2 PID command voltage 3 closed loop deviation incl sign 4 closed loop deviation absolute 5 actuato...

Страница 19: ...n loop position voltage back from the measured monitor voltage use the following formula Umes OL Umon 2 5V 2 The default setting is the position value in closed loop see No 0 sketch 3 monitor output 8...

Страница 20: ...is connected to this plug The actuator voltage goes to the piezo the position signal from the measurement system goes to the DSP and the integrated actuator information is stored on an ID chip which g...

Страница 21: ...ohm operation time of actuator since shipping minutes rgver version number of loop controller request table 6 commands without values commands with values command value Enter command description value...

Страница 22: ...amplitude sine 0 to 100 gosin amplitude offset sine 0 to 100 gfsin generator frequency sine 0 1 to 9999 9 Hz gatri generator amplitude triangle 0 to 100 gotri amplitude offset triangle 0 to 100 gftri...

Страница 23: ...rface every 500 milliseconds This value can then be read out via the interface Subsequent increasing of the query sequence for this value does not increase the refreshing rate If the piezoelectric act...

Страница 24: ...11 10 9 211 210 29 0 0 0 generator off 0 0 1 sine on 0 1 0 triangle on 0 1 1 rectangle on 1 0 0 noise on 1 0 1 sweep on 0 512 1024 1536 2048 2560 12 212 0 notch filter off 1 notch filter on 0 4096 13...

Страница 25: ...of the impulses trglen 1 or decrease the movement speed of the actuator Furthermore you must be sure that the trigger range between trgss and trgse passes through plus 0 2 of the total stroke otherwis...

Страница 26: ...xt Trigger position is set to 10 m the trigger impulse will be generated when the 10 m position is reached from a lower position than 10 m rising edge Extended trigger functions trgedge 4 5 7 The func...

Страница 27: ...ed This principle depends on whether or not trgss and trgse are bordered by a working area that crosses at least 0 2 of total stroke out of the borders trgss lower trigger position this is the lowest...

Страница 28: ...triangle This will require that the relevant functional parameters be set frequency amplitude offset or symmetry The function generator does not need to be activated gfkt 0 To select a scan set the sc...

Страница 29: ...combined use of trigger generation and scan function permits a highly exact scan of a probe Acceleration forces and with it oscillations are minimized by using a sine function and actions can be initi...

Страница 30: ...OD input the actuator is in the most negative position pos 1 of its deviation pos 1 to pos 4 see sketch 2 By pressing the knob in the operation mode changes to closed loop and the OL CL LED changes to...

Страница 31: ...onant frequency Use function generator in the menu of the actuator Set the amplitude to 5 the offset to 0 and the sweep time to 1 1sec decade Set the amplifier to open loop OL CL LED lights green With...

Страница 32: ...justments reduce the ki value Reduce the kd value Check whether the function generator is still working read back parameters always deviate at the same level from the digital target value Please switc...

Страница 33: ...ng in nm resolution you must warm up the amplifier 2 hours before use A constant temperature is beneficial Consider that a variation of 5 Kelvin results in elongation by 13 m in steel with a length of...

Страница 34: ...www newport com 34 12 Your Notes...