The  command  for  the  controller  consists  of  the  analog  signal  applied  to  the  MOD input,  the 
digital  value  given  by  the 

encoder  “OFFSET”  and  the  digital  value  from  the  RS232  interface. 

The slew rate of the amplifier can be adapted to your system using the "slew rate" limiter or the 
4th order low pass filter, i.e. frequencies, which might stimulate resonances, can be suppressed 
before they interfere with the closed loop. The slew rate of this set value is adjustable. 

 

The  PID-controller  calculates  the  difference  (err)  between  this  input  (com)  and  the  value  from 
the measurement system (mes). 

 

 

err = com 

– mes 

 

 

com = command 

 

 

 

 

 

mes = position signal 

 

The proportional term (kp) amplifies the control deviation without reducing frequency and drives 
the controller until the difference between the sensed motion and the command: 

 

 

yp = kp * err 

 

 

kp = adjustable gain 

 

 

 

 

yp = output of p-term 

 

The P-controller can

’t eliminate the error completely, because it needs a deviation to drive. To 

minimize the permanent offset of the P-term an integral action (I-term) is required. Ts is the time 
constant governing the time it takes for the output to get a certain value. For a step input it is the 
time taken for the output to equal the input. 

 

yi = yi + ki * err * Ts 

 

Ts = 1 / sample frequency (50 kHz) 

 

 

 

 

 

1/ki  = time constant 

 

 

 

 

 

yi = output of i-term 

In general, the differential term combats oscillation (it adds damping) and increases the reaction 
speed of the PI

–controller: 

 

yd = kd * 1/Ts * (err 

– err[n-1])  err[n-1] = control deviation previous sample 

 

 

 

 

 

kd = differential time constant 

 

 

 

 

 

yd = output of d-term 

    
Be  careful  when  using  the  d-term,  because  stochastic  errors,  like  noise,  cause  extreme 
reactions. The addition of these 3 terms generates a PID

–controller. The output of the controller 

is the set value for the power amplifier to drive the piezo actuator: 

 

y = yp + yi + yd   

 

y = output of PID-controller 

In open loop mode, the PID-controller is bridged and the command input controls the amplifier. 
 
Using a subsequent steep notch filter the main resonant frequency will be damped by another 
order of magnitude. While using open loop you can also switch on the notch filter to reduce the 
stimulation of the resonant frequency. 
The PID-specific parameters kp, ki, and kd are stored in the actuator

’s ID-chip by default. These 

parameters will work for most applications. Depending on your special application and load, the 
mechanical response can be optimized.

 

Содержание NPC DIG Series

Страница 1: ...n Manual Digital Piezo Amplifier Series NPCxxxDIG Models NPC50DIG NPC300DIG Please read carefully before switching on the power Please see safety instructions for using piezoelectric actuators and pow...

Страница 2: ...www newport com 2 English version last change 2017 02 16 by TP...

Страница 3: ...3...

Страница 4: ...for checking the function of the system quick start 11 8 How to operate the digital amplifier series NPCxxxDIG 12 8 1 Common Introduction 12 8 2 User Elements Connections 12 8 2 1 Front Panel 12 8 2...

Страница 5: ...rporation You will also find additional information regarding piezoelectric products Definition All systems from Newport Corporation such as electronics actuators and optical systems are called units...

Страница 6: ...uction and form put by us into circulation is in accordance with all relevant essential requirements of the EMC Directive 2014 30 EU This declaration is no longer valid if the device is modified witho...

Страница 7: ...l occur After excitation of the actuators by a voltage in the upper control range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will o...

Страница 8: ...regular waste Instead it is the user responsibility to dispose of waste equipment according to the local laws The separate collection and recycling of the waste equipment at the time of disposal will...

Страница 9: ...rs Only work with the units in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please only use original parts from Newport Corporation Newport C...

Страница 10: ...cables e g power cords sensor cables actuator cables optical cables Do not block ventilated openings or place the units near a radiator oven or other heat sources Plug in the power cord completely so...

Страница 11: ...r shape should be parallel each to each other and not have any scratches If there is any damage to the system please contact our local representative immediately If the packaging material is damaged p...

Страница 12: ...high speed positioning with the highest accuracy available It includes rise time optimization and an active oscillation damping for every special application The NPCxxxDIG comes with an auto calibrati...

Страница 13: ...13 8 2 2 Back Panel...

Страница 14: ...www newport com 14 8 3 Function The following sketch shows the function groups of the amplifier sketch 1 function groups of the amplifier...

Страница 15: ...akes for the output to get a certain value For a step input it is the time taken for the output to equal the input yi yi ki err Ts Ts 1 sample frequency 50 kHz 1 ki time constant yi output of i term I...

Страница 16: ...er of magnitude While using open loop you can also switch on the notch filter to reduce stimulation of the resonant frequency Using the notch filter might increase noise The PID specific parameters kp...

Страница 17: ...500Hz Actuator measurement connector PIEZO 15pin D Sub plug Monitor output 0 10V programmable signal source Monitor output impedance 1k Modulation input 0 10V disconnectable Modulation input impedanc...

Страница 18: ...ription value monsrc value monitor output default 0 0 position value in closed loop 1 reference input 2 PID command voltage 3 closed loop deviation incl sign 4 closed loop deviation absolute 5 actuato...

Страница 19: ...n loop position voltage back from the measured monitor voltage use the following formula Umes OL Umon 2 5V 2 The default setting is the position value in closed loop see No 0 sketch 3 monitor output 8...

Страница 20: ...is connected to this plug The actuator voltage goes to the piezo the position signal from the measurement system goes to the DSP and the integrated actuator information is stored on an ID chip which g...

Страница 21: ...ohm operation time of actuator since shipping minutes rgver version number of loop controller request table 6 commands without values commands with values command value Enter command description value...

Страница 22: ...amplitude sine 0 to 100 gosin amplitude offset sine 0 to 100 gfsin generator frequency sine 0 1 to 9999 9 Hz gatri generator amplitude triangle 0 to 100 gotri amplitude offset triangle 0 to 100 gftri...

Страница 23: ...rface every 500 milliseconds This value can then be read out via the interface Subsequent increasing of the query sequence for this value does not increase the refreshing rate If the piezoelectric act...

Страница 24: ...11 10 9 211 210 29 0 0 0 generator off 0 0 1 sine on 0 1 0 triangle on 0 1 1 rectangle on 1 0 0 noise on 1 0 1 sweep on 0 512 1024 1536 2048 2560 12 212 0 notch filter off 1 notch filter on 0 4096 13...

Страница 25: ...of the impulses trglen 1 or decrease the movement speed of the actuator Furthermore you must be sure that the trigger range between trgss and trgse passes through plus 0 2 of the total stroke otherwis...

Страница 26: ...xt Trigger position is set to 10 m the trigger impulse will be generated when the 10 m position is reached from a lower position than 10 m rising edge Extended trigger functions trgedge 4 5 7 The func...

Страница 27: ...ed This principle depends on whether or not trgss and trgse are bordered by a working area that crosses at least 0 2 of total stroke out of the borders trgss lower trigger position this is the lowest...

Страница 28: ...triangle This will require that the relevant functional parameters be set frequency amplitude offset or symmetry The function generator does not need to be activated gfkt 0 To select a scan set the sc...

Страница 29: ...combined use of trigger generation and scan function permits a highly exact scan of a probe Acceleration forces and with it oscillations are minimized by using a sine function and actions can be initi...

Страница 30: ...OD input the actuator is in the most negative position pos 1 of its deviation pos 1 to pos 4 see sketch 2 By pressing the knob in the operation mode changes to closed loop and the OL CL LED changes to...

Страница 31: ...onant frequency Use function generator in the menu of the actuator Set the amplitude to 5 the offset to 0 and the sweep time to 1 1sec decade Set the amplifier to open loop OL CL LED lights green With...

Страница 32: ...justments reduce the ki value Reduce the kd value Check whether the function generator is still working read back parameters always deviate at the same level from the digital target value Please switc...

Страница 33: ...ng in nm resolution you must warm up the amplifier 2 hours before use A constant temperature is beneficial Consider that a variation of 5 Kelvin results in elongation by 13 m in steel with a length of...

Страница 34: ...www newport com 34 12 Your Notes...

Отзывы: