Command Set
65
SR
set right travel limit
USAGE
IMM
♦
MIP
SYNTAX
xxSRnn or xxSR?
PARAMETERS
Description
xx
[ int ]
-
Controller number
nn
[ int ]
-
Positive software limit
Range
xx
-
0
to
255
nn
-
-60000
to 1200000
Units
xx
-
None
nn
-
Micro-steps
Defaults
xx
Missing:
None
out of range:
None
nn
missing:
Error 37, Parameter Missing
out of range:
Error 7, Parameter Out of
Range
Error 230, Command not
allowed during motion
DESCRIPTION
This command will set the value of the negative software limits.
NOTE:
The value of positive software limit should be larger
than the value of the Negative Software limit.
RETURNS
If the “?” sign takes the place of
nn
value, this command reports
the value of the Positive Software limit.
REL.
COMMANDS
SL
-
Negative Software Limit
PA
Absolute Move
Содержание NewStep NSA12
Страница 1: ...Actuator and Motion Controller NewStep User s Manual TM...
Страница 20: ...20 Getting Started This page is intentionally left blank...
Страница 25: ...Operating NewStep 25 4 1 3 Single Actuator no Computer Interface minimal configuration...
Страница 26: ...26 Operating NewStep 4 1 4 Single Actuator with Computer Interface...
Страница 27: ...Operating NewStep 27 4 1 5 Two Actuators no Computer Interface...
Страница 28: ...28 Operating NewStep 4 1 6 Two Actuators with Computer Interface...
Страница 29: ...Operating NewStep 29 4 1 7 Multiple Actuators with Computer Interface...
Страница 32: ...32 Operating NewStep This page is intentionally left blank...