Command Set
47
AU
set maximum acceleration
USAGE
IMM
♦
MIP
SYNTAX
xx
AU
nn or xx
AU
?
PARAMETERS
Description
xx
[ int ]
-
Controller number
nn
[float ]
-
Acceleration value
Range
xx
-
0 to 255
nn
-
0 to 500 or xxAU? to read current
setting
Units
xx
-
None
nn
-
Full Steps/second
2
Defaults
xx
missing:
None
out of range:
None
nn
missing:
Error 38, Parameter missing
out of range:
Error 7, Parameter Out of Range
Error 230, Command not allowed
during motion
DESCRIPTION
This command is used to set the maximum acceleration value for the
actuator. It’s execution is immediate. However, if there is motion in
progress the command is ignored.
RETURNS
If the “?” sign takes the place of
nn
value, this command reports the
current setting.
REL.
COMMANDS
AC
-
set acceleration and deceleration
PA
execute an absolute motion
PR
execute a relative motion
Содержание NewStep NSA12
Страница 1: ...Actuator and Motion Controller NewStep User s Manual TM...
Страница 20: ...20 Getting Started This page is intentionally left blank...
Страница 25: ...Operating NewStep 25 4 1 3 Single Actuator no Computer Interface minimal configuration...
Страница 26: ...26 Operating NewStep 4 1 4 Single Actuator with Computer Interface...
Страница 27: ...Operating NewStep 27 4 1 5 Two Actuators no Computer Interface...
Страница 28: ...28 Operating NewStep 4 1 6 Two Actuators with Computer Interface...
Страница 29: ...Operating NewStep 29 4 1 7 Multiple Actuators with Computer Interface...
Страница 32: ...32 Operating NewStep This page is intentionally left blank...