78
Remote Command Set
QM
Description
Motor type set command.
Syntax
xx
QM
nn
Remarks
This command is used to manually set the motor type of an axis. Send the Motors Check
(MC) command to have the controller determine what motors (if any) are connected.
Note that for motor type ‘Tiny’, velocity should not exceed 1750 step/sec. To save the
setting to non-volatile memory, issue the Save (SM) command.
Note that the controller may change this setting if auto motor detection is enabled by
setting bit number 0 in the configuration register to 0 (default) wit ZZ command. When
auto motor detection is enabled the controller checks motor presence and type
automatically during all moves and updates QM status accordingly.
Argument
Value
Description
xx
1 to 4
Axis number
nn
0
No motor connected
1
Motor type unknown
2
‘Tiny’ Motor
3
‘Standard’ motor
Example
2QM3
(Set motor 2 to type ‘Standard’ Picomotor)
SM
(Save new settings to memory)
See Also
QM?, MC, ZZ, SM
Содержание New Focus Picomotor 8742
Страница 1: ...Picomotor Controller Driver User s Manual Model 8742 ...
Страница 53: ...Computer Interfacing 53 Cycle Tab Cycle Motion ...
Страница 54: ...54 Computer Interfacing Terminal Tab Command Line Terminal ...
Страница 57: ...Computer Interfacing 57 Options Window Connection Options Setup ...
Страница 58: ...58 Computer Interfacing Properties Window USB and Ethernet Properties ...
Страница 59: ...Computer Interfacing 59 Controller Scan Scan RS 485 LAN ...
Страница 60: ...60 Computer Interfacing Address Conflict Resolution Window Automatic Address Conflict Resolution ...
Страница 61: ...Computer Interfacing 61 Device Address Window View Change Controller Address ...