11
EDH0211En1051 — 12/18
IMS-V Series High-Performance Linear Stages for Vertical Use
WARNING
This cable is shielded correctly. For a correct operation, make sure to
lock connectors (ground continuity provided by the cable).
WARNING
Keep this cable at a safe distance from other electrical cables in your
environment to avoid potential cross talk.
6.0 —
Connection to Non-Newport Electronics
6.1
Connections
WARNING
Newport is not responsible for malfunction or damage of IMS-V stages
when used with non-Newport controllers.
WARNING
Newport guarantees
“
”
compliance of IMS-V stages only if used with
Newport cables and controllers.
It is the customer’s responsibility to modify the cable and take care of
sensor signal connections, when using the stage with non-Newport
controllers.
End-of-Runs and Mechanical Zero are open collector type with a 5.6 V
protective Zener diode.
I
in
max.: 16 mA
V max.: 5.25 V
NEWPORT
STAGE
5.6 V