April 2018
8
FPM-8220
Store Pressing
STORE
allows the user to save an instrument setup, including
gain range, wavelength, display mode, filter mode, and user calibration
offset value, in bins numbered 1-10. To save a setup, first press the
STORE
pushbutton, then use the
UP ARROW
and the
DOWN
ARROW
to
select the appropriate store bin and press
ENTER.
Wavelength By
pressing
WAVELENGTH (
λ
)
and using the
UP
ARROW
and the
DOWN
ARROW,
the user can adjust the wavelength to that of the input light for
accurate power measurements. The wavelength adjustment range is
dependent upon the FMH-8700 series Fiber Optic Measurement Head
connected to the FPM-8220.
Local
When the instrument is in remote operation mode, pressing the
RECALL
pushbutton will put the instrument back to local (front panel) control mode.
Remote
Upon receipt of a command through either the USB or GPIB interface bus,
the instrument automatically enters remote mode; indicated by
RMT
in the
upper right corner of the display. During remote communication, the front
panel will be locked. Pressing the
RECALL
pushbutton will unlock the
front panel.
GPIB Address
Pressing
RECALL
and the
UP ARROW
pushbuttons simultaneously will
put the instrument in the GPIB address adjust mode. The currently stored
GPIB address will appear in the parameter line of the display. Pressing the
UP ARROW
or the
DOWN ARROW
changes the address number.
Mode
dBm/W Pressing
dBm/W
changes the measurement dimensions from dBm to
watts. Pressing the button again changes the dimensions back.
REF
Pressing and immediately releasing the
REF
pushbutton puts the
instrument into reference measurement mode where the displayed
measurement is relative to the set reference value. When in reference
mode, the display’s enunciator changes to dB or W, depending on the
mode, and a delta symbol is displayed, right justified, in the enunciator
field.
To set a new reference value, hold
REF
for five seconds.
View Ref
To view the set reference value, press the
dBm/W
and
REF
pushbuttons simultaneously. The value is displayed for 3 seconds in
the parameter line.
Auto/Man
Pressing
AUTO/MAN
changes the instrument’s measurement mode to
either auto, where the gain range is changed through a firmware
algorithm depending on the input, or manual, where the gain range is
set by the user. If the instrument is in auto measurement mode,
pressing either of the arrow pushbuttons changes the measurement
mode to manual. In manual mode, the gain range is displayed on the
parameter line.
Содержание FPM-8220
Страница 1: ...User s Guide Fiber Optic Power Meter FPM 8220 70044001 April 2018...
Страница 2: ......
Страница 6: ...April 2018 iv FPM 8220 This page was intentially left blank...
Страница 12: ...April 2018 x FPM 8220 This page was intentionally left blank...
Страница 16: ...April 2018 4 FPM 8220 Specifications...
Страница 34: ...April 2018 22 FPM 8220...
Страница 78: ...April 2018 66 FPM 8220...