NewMar EV-40 Скачать руководство пользователя страница 4

P.O. Box 1306

Newport Beach

California 92663

   

  

Phone: 714-751-0488  

     Fax: 714-957-1621

     E-Mail: [email protected]

www.newmarEVpower.com

2.  To  reduce  the  risk  of  battery  explosion,  follow  these 

instructions  and  those  published  by  the  battery 

manufacturer and by the manufacturer of any equipment 

you intend to use in the vicinity of the battery. Review 

cautionary markings on these products and on the engine.

PERSONAL PRECAUTIONS

1. Someone should be within range of your voice or close 

enough to come to your aid when you work near a lead-

acid battery.

2. Have plenty of fresh water and soap nearby in case 

battery acid contacts skin, clothing, or eyes.

3.  Wear  complete  eye  and  clothing  protection.  Avoid 

touching your eyes while working near a battery.

4.  If  battery  acid  contacts  skin  or  clothing,  wash 

immediately with soap and water. If battery acid enters the 

eye, immediately flood eye with running cold water for at 

least 10 minutes and get medical attention immediately.

5. NEVER smoke or allow a spark or flame in the vicinity 

of the battery or engine.

6. Be extra cautious to reduce the risk of dropping a metal 

tool  onto  the  battery.  It  might  spark  or  short-circuit  the 

battery or other electrical part and cause an explosion.

7. Remove personal metal items such as rings, bracelets, 

necklaces, and watches when working with a lead-acid 

battery. A lead-acid battery can produce a short-circuit 

high enough to weld a ring or the like metal, causing a 

severe burn.

8. Use the battery charger for charging gel-cell or flooded 

lead-acid batteries only. It is not intended to supply power 

to a low voltage electrical system other than in a starter-

motor application. Do not use the charger for charging 

dry-cell  batteries  that  are  commonly  used  with  home 

applications. These batteries may burst and cause injury 

to persons and damage to property.

9. NEVER charge a frozen battery.

PREPARING TO CHARGE

1. Be sure the area around the battery is well ventilated.

2. Clean battery terminals. Be careful to keep corrosion 

from coming in contact with eyes.

3.  Add  distilled  water  in  each  cell  until  battery  acid 

reaches  level  specified  by  battery  manufacturer.  This 

helps purge excessive gas from cells. Do not overfill. For a 

battery without cell caps, carefully follow manufacturer’s 

recharging instructions.

4. Study all battery manufacturers’ specific precautions 

such as removing or not removing cell caps while charging 

and recommended rates of charge.

GROUND AND AC POWER CORD CONNECTION

1.  The  charger  should  be  grounded  to  reduce  risk  of 

electrical shock.

2. The Charger is provided with IEC certified AC power cord. 

If, for any reason, the plug on the cord must be changed or 

replaced, observe color coding of the AC wiring as follows:

Black………..................................…AC Hot (fused) 

White………….................................AC Neutral 

Green……...................…......………AC Ground (safety/earth)

The charger must be plugged or hard wired into an outlet 

that is properly installed and grounded in accordance 

with all local codes and ordinances.

DANGER:

 Never alter the AC cord or plug provided, unless 

it is absolutely necessary for use with the AC outlet which 

conforms to all relevant electrical codes. Any modification 

of the cord must only be done by a qualified electrician. 

Improper  cord/outlet  connection  can  result  in  a  risk  of 

electrical shock.

EXTERNAL  CONNECTIONS  TO  THE  CHARGER  SHALL 

COMPLY WITH UL RECOMMENDATIONS, NEC, or NFPA 

STANDARDS

III) INSTALLATION

A) Materials Provided

The charger is provided completely assembled and ready 

for installation. Because of numerous installation variables, 

the installer will need to provide four suitable ¼” mounting 

screws/washers, as well as DC output wiring and battery 

connectors.  Proper  sizes  and  gauges  for  the  wire  and 

connectors are noted in 

Section III-D

 following. 

B) Location

The charger should be mounted on a wall, vehicle floor, 

ventilated compartment or other suitable surface as close 

to the batteries to be charged as possible. Do not mount 

the charger directly over the batteries as fumes may cause 

excessive corrosion. The area should be well ventilated 

and free from excessive moisture, exhaust manifolds, and 

battery fumes.

For  maximum  performance,  the  charger  should  not  be 

located in an area of extreme high temperature.

4

Содержание EV-40

Страница 1: ...B Location 4 C Mounting 5 D DC Output Wiring Battery Auxiliary Loads 5 E AC Input Wiring 7 IV OPERATION 7 A Three Stage Charge Regimen 7 B Time Out Circuit 8 C Gel Cell AGM Lead Acid Selector Switch 8...

Страница 2: ...d AGM Pg 8 Battery Output Connector Block 40 Amps Maximum Pg 5 Auxiliary Output Connector Block 15 Amps Maximum Air Pump Hand Lights Radios Pg 5 Slide in and Lock Mounting Plate optional Pg 5 DC Outpu...

Страница 3: ...f batteries may burst causing personal injury and damage 4 Do not expose charger to rain or spray 5 Use of an attachment not recommended or sold by NEWMAR may result in a risk of fire electric shock o...

Страница 4: ...areful to keep corrosion from coming in contact with eyes 3 Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cell...

Страница 5: ...n be oriented to the rear of the assembly or facing out at installers discretion Reference Figure 2 Figure 2 Optional Slide In Bracket Slide in and Lock Mounting System Description The Slide in and Lo...

Страница 6: ...er must be removed To do this requires removal of two screws from the front of the unit and five screws on each side The DC fuse is mounted on the main circuit board Be sure to replace with the same t...

Страница 7: ...protected by an internal input fuse This indicates the chargerhasaninternalshort returnthechargerforservice IV OPERATION A Three Stage Charge Regimen The Battery Charger features the three stage charg...

Страница 8: ...for a gel cell than a lead acid battery The ideal charge float regimen has been programmed into the Charger for either sealed gel cell or flooded lead acid batteries Simply make the proper selection f...

Страница 9: ...input fuse does need replacing be sure to replace it with the same type and value for continue protection B Constant Versus Occasional Use In general it is recommended that the charger be left connect...

Страница 10: ...in line if for instance the battery must be removed for any purpose and AC is still available All but the most sensitive DC powered electronic devices will function as normally as if powered by a batt...

Страница 11: ...e 2 Charger output is not properly connected to batteries 3 Blown output fuse 4 Defective charger 1 Usingavoltmeter confirm ACinput voltage check input connections 2 Refer to DC wiring installation di...

Страница 12: ...may damage charger 3 Check wiring for open connection F EVM 12 1 bar graph works but Charger On LED does not Remote meter connector terminals 3 4 shorted together or open wire Remove short and re con...

Страница 13: ...gravity Some chemicals may also create an insulating coating on the battery plates which will retard current flow The rate that water is lost by the battery is dependent on several factors battery co...

Страница 14: ...P O Box 1306 Newport Beach California 92663 Phone 714 751 0488 Fax 714 957 1621 E Mail techservice newmarpower com www newmarEVpower com Unit Dimensional Drawing 14...