As the alternator starts to charge the battery, the charger 

output will decrease. When the battery voltage exceeds 

the rated output voltage of the charger, no current will 

flow from the charger as long as the batteries are in this 

high state of charge. 

E)  Operation  as  a  DC  Power  Supply  (stand  alone  DC 

Power Source)

Most  battery  chargers  are  not  suitable  for  powering 

electronic devices directly, without a battery attached to 

the output, as the high ripple and pulsing DC output (i.e., 

rectified AC output) can interfere with the operation of the 

device. The EV charger is different. It employs a circuit that 

produces an extremely well-filtered DC output. Therefore the 

charger is able to power virtually any DC powered device 

(within the unit’s rating) without the battery attached in-

line (if, for instance, the battery must be removed for any 

purpose and AC is still available). All but the most sensitive 

DC powered electronic devices will function as normally 

as if powered by a battery. In addition, the current limiting 

circuitry enables the charger to handle the high start-up 

surges associated with inductive loads, such as DC motors.

VII) Specifications

 

INPUT RANGE (ALL MODELS): 

90-264; 47-63 HZ (automatic) 

EV-40

6.8/3.4

12

40

OUTPUT VOLTAGES:

Setting

Charge

@ 50% Load

Float @ .1 Amp 

Load

Gel-Cell

14.0V DC

13.6V DC

Lead-Acid/AGM

14.2V DC

13.4V DC

Temperature Ratings:

 -20° C to + 60° C; Derate linearly 

from 100% @ 50° C to 60% @ 60° C

INPUT/OUTPUT FUSE VALUES:

 

Model

DC Output Fuse

EV-40

ATC-30 (2 each)

Case Size/Weight:

 3.12” H x 6.8” W x 13.12” D; 7 Lbs.

                              7.92 x 17.27 x 33.32 (cm); 3.2 Kgs.

Mounting Dimensions: 

See page 13

PROTECTIONFEATURES: 

Input Fuse; Output fuse for reverse polarity protection; 

Current limiting; Time and load controlled high rate 

charge circuit; Ignition protected; IP 21

Compliances:  

                                                                                                                                        

        Safety: EN60335-1                                                                                                                                        

        EMC: IEC 1000-4-2,     

        EN55014                                                                                                                                          

                                                                                                          

Model

Input Amps 

115/230V

Ouput

Volts

Amps (Cont

EV-40 Battery Charger

10

Содержание EV-40

Страница 1: ...B Location 4 C Mounting 5 D DC Output Wiring Battery Auxiliary Loads 5 E AC Input Wiring 7 IV OPERATION 7 A Three Stage Charge Regimen 7 B Time Out Circuit 8 C Gel Cell AGM Lead Acid Selector Switch 8...

Страница 2: ...d AGM Pg 8 Battery Output Connector Block 40 Amps Maximum Pg 5 Auxiliary Output Connector Block 15 Amps Maximum Air Pump Hand Lights Radios Pg 5 Slide in and Lock Mounting Plate optional Pg 5 DC Outpu...

Страница 3: ...f batteries may burst causing personal injury and damage 4 Do not expose charger to rain or spray 5 Use of an attachment not recommended or sold by NEWMAR may result in a risk of fire electric shock o...

Страница 4: ...areful to keep corrosion from coming in contact with eyes 3 Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cell...

Страница 5: ...n be oriented to the rear of the assembly or facing out at installers discretion Reference Figure 2 Figure 2 Optional Slide In Bracket Slide in and Lock Mounting System Description The Slide in and Lo...

Страница 6: ...er must be removed To do this requires removal of two screws from the front of the unit and five screws on each side The DC fuse is mounted on the main circuit board Be sure to replace with the same t...

Страница 7: ...protected by an internal input fuse This indicates the chargerhasaninternalshort returnthechargerforservice IV OPERATION A Three Stage Charge Regimen The Battery Charger features the three stage charg...

Страница 8: ...for a gel cell than a lead acid battery The ideal charge float regimen has been programmed into the Charger for either sealed gel cell or flooded lead acid batteries Simply make the proper selection f...

Страница 9: ...input fuse does need replacing be sure to replace it with the same type and value for continue protection B Constant Versus Occasional Use In general it is recommended that the charger be left connect...

Страница 10: ...in line if for instance the battery must be removed for any purpose and AC is still available All but the most sensitive DC powered electronic devices will function as normally as if powered by a batt...

Страница 11: ...e 2 Charger output is not properly connected to batteries 3 Blown output fuse 4 Defective charger 1 Usingavoltmeter confirm ACinput voltage check input connections 2 Refer to DC wiring installation di...

Страница 12: ...may damage charger 3 Check wiring for open connection F EVM 12 1 bar graph works but Charger On LED does not Remote meter connector terminals 3 4 shorted together or open wire Remove short and re con...

Страница 13: ...gravity Some chemicals may also create an insulating coating on the battery plates which will retard current flow The rate that water is lost by the battery is dependent on several factors battery co...

Страница 14: ...P O Box 1306 Newport Beach California 92663 Phone 714 751 0488 Fax 714 957 1621 E Mail techservice newmarpower com www newmarEVpower com Unit Dimensional Drawing 14...