1) General Information 

The EV™ Series Battery Charger represents a new phase in 

charger design and performance. It’s ideal for application 

on  emergency  and  specialty  vehicles,  utilizing  “smart” 

switching  circuitry  which  puts  batteries  through  the 

optimum three-stage charge process, adapts for gel-cell, 

AGM or lead-acid batteries, is rated for continuous duty 

and  is  housed  in  an  aluminum  case  with  an  optional 

slide-in front access installation bracket.

Following is a brief listing of some of the more important 

features/options. Each is fully detailed later in this manual:

• Three step “smart” charging: bulk, absorption, float

• Gel-Cell/AGM/Lead-Acid switch selects optimum charge/

float voltages based on battery type

• 90-264VAC, 50-60 Hz input – can be used anywhere in 

the world

•    Current limited – prevents damage in case of overloading

•  Thermally  controlled  cooling  fan  allows  continuous 

operation at full-rated output

•  High  charge  voltage  time-out  circuit  prevents 

overcharging during continuous high amperage demand

•  Optional  Remote  Panel  allows  remote  monitoring  of 

charger status 

• Use as a power supply without in-line battery; allows 

continued  use  of  DC  powered  electronics  (when  AC  is 

available) in the event that batteries must be taken off-

line or removed

•  Auxiliary  output  for  electronics,  air  compressors,  and 

hand lights

II) Important Safety Instructions

1.  SAVE  THESE  INSTRUCTIONS  –  This  manual  contains 

important safety and operating instructions for the EV-40 

Battery Charger.

2. Before using this battery charger, read all instructions 

and cautionary markings on (1) the battery charger, (2) 

the battery, and (3) product powered by the battery.

3. CAUTION – To reduce the risk of injury, charge only 6 

cell  (12  volt  models)  gel-cell  or  lead-acid  rechargeable 

batteries.  Other  types  of  batteries  may  burst,  causing 

personal injury and damage.

4. Do not expose charger to rain or spray.

5.  Use  of  an  attachment  not  recommended  or  sold  by 

NEWMAR  may  result  in  a  risk  of  fire,  electric  shock  or 

injury to persons.

6. To reduce the risk of damage to the electric plug and 

cord  (if  plugged  into  an  AC  outlet),  pull  by  plug  rather 

than cord when disconnecting the charger.

7. Make sure the cord is located so that it will not be stepped 

on, tripped over, or otherwise subjected to damage or stress.

8. An extension cord should not be used unless absolutely 

necessary. Use of an improper cord could result in the risk 

of  fire  and  electric  shock.  If  an  extension  cord  must  be 

used, make sure:

A) That pins on the plug of the extension cord are the same 

number, size and shape as those on the plug of the charger.

B) That the extension cord is properly wired and in good 

electrical condition.

C) That the wire size is large enough for the AC amperage 

rating of the charger. Refer to the 

SPECIFICATIONS 

Section,  

page 10, to determine the full load input current of your 

charger, and then use the chart below to determine the 

correct gauge wire for any extension cord used.

25

50

100

150

16

14

12

10

9. Do not operate the charger with a damaged cord or 

plug; replace them immediately.

10. Do not operate the charger if it has received a sharp 

blow,  been  dropped,  or  otherwise  damaged;  take  to  a 

qualified serviceman.

11. Do not disassemble the charger; take it to a qualified 

serviceman when service or repair is necessary. Incorrect 

reassembly may result in a risk of electric shock and fire.

12.  To  reduce  the  risk  of  electric  shock,  disconnect 

the  charger  from  AC  source  before  attempting  any 

maintenance or cleaning.

WARNING – RISK OF EXPLOSIVE GASES

1. WORKING IN THE VICINITY OF A LEAD-ACID BATTERY 

IS  DANGEROUS.  BATTERIES  GENERATE  EXPLOSIVE 

GASES  DURING  NORMAL  BATTERY  OPERATION.  FOR 

THIS REASON, IT IS OF THE UTMOST IMPORTANCE THAT 

BEFORE INSTALLING AND USING YOUR CHARGER, READ 

THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.

RECOMMENDED MINIMUM AWG 

SIZE FOR EXTENSION CORDS FOR 

EV BATTERY CHARGER

Length of Cord, Feet

Size of Cord, AWG

3

Содержание EV-40

Страница 1: ...B Location 4 C Mounting 5 D DC Output Wiring Battery Auxiliary Loads 5 E AC Input Wiring 7 IV OPERATION 7 A Three Stage Charge Regimen 7 B Time Out Circuit 8 C Gel Cell AGM Lead Acid Selector Switch 8...

Страница 2: ...d AGM Pg 8 Battery Output Connector Block 40 Amps Maximum Pg 5 Auxiliary Output Connector Block 15 Amps Maximum Air Pump Hand Lights Radios Pg 5 Slide in and Lock Mounting Plate optional Pg 5 DC Outpu...

Страница 3: ...f batteries may burst causing personal injury and damage 4 Do not expose charger to rain or spray 5 Use of an attachment not recommended or sold by NEWMAR may result in a risk of fire electric shock o...

Страница 4: ...areful to keep corrosion from coming in contact with eyes 3 Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cell...

Страница 5: ...n be oriented to the rear of the assembly or facing out at installers discretion Reference Figure 2 Figure 2 Optional Slide In Bracket Slide in and Lock Mounting System Description The Slide in and Lo...

Страница 6: ...er must be removed To do this requires removal of two screws from the front of the unit and five screws on each side The DC fuse is mounted on the main circuit board Be sure to replace with the same t...

Страница 7: ...protected by an internal input fuse This indicates the chargerhasaninternalshort returnthechargerforservice IV OPERATION A Three Stage Charge Regimen The Battery Charger features the three stage charg...

Страница 8: ...for a gel cell than a lead acid battery The ideal charge float regimen has been programmed into the Charger for either sealed gel cell or flooded lead acid batteries Simply make the proper selection f...

Страница 9: ...input fuse does need replacing be sure to replace it with the same type and value for continue protection B Constant Versus Occasional Use In general it is recommended that the charger be left connect...

Страница 10: ...in line if for instance the battery must be removed for any purpose and AC is still available All but the most sensitive DC powered electronic devices will function as normally as if powered by a batt...

Страница 11: ...e 2 Charger output is not properly connected to batteries 3 Blown output fuse 4 Defective charger 1 Usingavoltmeter confirm ACinput voltage check input connections 2 Refer to DC wiring installation di...

Страница 12: ...may damage charger 3 Check wiring for open connection F EVM 12 1 bar graph works but Charger On LED does not Remote meter connector terminals 3 4 shorted together or open wire Remove short and re con...

Страница 13: ...gravity Some chemicals may also create an insulating coating on the battery plates which will retard current flow The rate that water is lost by the battery is dependent on several factors battery co...

Страница 14: ...P O Box 1306 Newport Beach California 92663 Phone 714 751 0488 Fax 714 957 1621 E Mail techservice newmarpower com www newmarEVpower com Unit Dimensional Drawing 14...