6
Emission data.
Mean CnHm emission @ (13% 02),
mg/Nm3
90 Nmg/m3
Mean CO emission
@ (13% 02), mg/Nm3
1354 Nmg/m3
Mean NOx emission
@ (13% 02), mg/Nm3
97 Nmg/m3
Din Plus particulates
@ 13% 02: 930mg/Nm3
10 Nmg/m3
Technical data according to EN 13240+A2:2004.
Fuel: Approved Smokeless fuels (Maxibrite used for tests).
Nominal heat output:
5.0kw
Flue gas mass flow:
4.4 g/sec
Recommended chimney draught:
12.5 Pa
Net Efficiency:
77.4 %
Verified Seasonal Efficiency:
67.4%
CO emission (13% O
2
):
0.11%
Mean flue gas temperature, at date of test:
280
0
C
Operational mode:
Intermittent
Emission data.
Mean CnHm emission @ (13% 02)
mg/Nm3
17 Nmg/m3
Mean CO emission
@ (13% 02), mg/Nm3
1375 Nmg/m3
Mean NOx emission
@ (13% 02) mg/Nm3
107 Nmg/m3
Din Plus particulates
@ 13% 02: 930 mg/Nm3
18 Nmg/m3