Newco VIP-LD Скачать руководство пользователя страница 5

Temperature Override - Turns the tank heater on at the start of a brew cycle to the maximum setting for 1 minute. 
This assures a more uniform brew temperature and reduces the recovery time required for rebrewing. As an 
additional safety check on the heater circuit the control board continuously monitors how long the element is on. If 
the run time exceeds 30 minutes the tank element is shut down and an error message is produced. See the 
following section for an explanation of all error messages. 

 

Service Alert System - Monitors key elements of brewer operation and shuts brewer down if an error condition 
occurs. If the tank heater element runs for more than 30 minutes continuously, the fill valve runs for more than 6 
minutes (1-1/2 minutes during brew cycle) continuously without probe contact or if the temperature sensor opens or 
shorts this will trigger the system to shut down. The service alert system illuminates the various indicator lights on 
the front of the brewer to indicate the type of error encountered. The table below list the different error codes 
produced by the service alert system, the posssible cause and what to check when the brewer will not operate. 

 

Error Code: 

Problem Area: 

Cause: 

Check: 

Autobrew/Heating & 
brewing lights on steady 

Water Fill 

System detects that fill valve has run for 6 min. (1-1/2 
min. during brew cycle) w/o making contact with probe. 

Water supply to brewer, water filters & 
water probe to see if limed up. 

Autobrew/Heating & 
ready lights on steady 

Tank Heater 

Tank heating system has run for 20 minutes. 

Tank heater relay, tank heater,  
limit thermostat. 

Auto Brew/heating& 
ready lights on steady 

See cause 

Blue wire is not connected to either black or  
Red wire 

 Blue wire connection. Black to enable 
Auto Arm or red to Disable Auto Arm 

Autobrew/Heating & half 
brew lights on steady 

Temperature Probe 

Thermistor is open. 

Replace Thermistor. 

Autobrew/Heating & full 
brew lights on steady 

Temperature Probe 

Thermistor shorted. 

Replace Thermistor. 

IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR, THE BREWER CAN BE RESET BY HOLDING DOWN THE 
CANCEL BUTTON FOR APPROXIMATELY 5 SECONDS.  ERROR WILL CLEAR. 

REPLACEMENT PARTS LIST 

Part No  Description 

Part No  Description 

Tank Components 

Expansion Pan Parts 

110777  Element, tank, 1250 W 120 V 

111164  O-ring, exp pan, 6.484 ID x .139 W 

110792  Element, tank, 1400 W 120 V 

111176  Spring, check valve, expansion pan 

110791  Element, tank, 1550 W 120 V 

111226  Cover, expansion pan 

110762  Protector, element 

111227  Pan, expansion 

110764  Washer, element 

111228  Retainer, Ball 

110765  Screws, element 

111401  Ball, 1/2 diameter 

110766  Washer, element, locking 

111402  Screw, #6 x 3/8", for plastic 

110767  Ring tab 

111403  Screw, #4 x 3/8", for plastic 

110752  Seal, element 

111519  Level probe 

110758  O-ring, Tank, 5.975 ID x .275 W 

704222  Gasket, pan outlet, 4 holes 

111080  Lid, plastic 

110978  Sprayhead fitting ass'y 

111153 Sensor, 

temperature 

 

 

  

Electrical 

Components 

Valves and faucet 

110626  Switch, On/Off, DPST, rocker 

111050  Valve, Inlet 

110378  Board, display 

110305  Flow control, PDS, low flow 

111515  Board, control 

111396  Faucet 

105057  Relay, heater, 12 V coil 

110506  Clamp, drain tube 

 

 

111517  Insert, 3/8 tube insert 

Miscelaneous components 

  

110985 

Brewbasket 

Tubing and gaskets 104010 

Brewrail, 

RH 

152218  Tubing, Silicone, 1/4 ID x 3/8 OD 

104011  Brewrail, LH 

152213  Tubing, Silicone, 3/8 ID x 5/8 OD 

100024  Sprayhead, S/S, 5 hole 

102544  Tubing, Silicone, 3/8 ID x 1/2 OD 

201173  Nut, sprayhead, 7/16-20 

101931  Tubing, Silicone, 5/8 ID x 3/4 OD 

701985  Sprayhead tube assembly 

111105  Nipple, fitting, Silicone 

110381  Spacer, 5/16" hex, display board 

100025  Gasket, sprayhead 

110991  Screw, 6-32 x 3/16, PPHMS, Nylon 

102836  Grommet, probe & thermistor 

108014  Access Plate 

 

 

111198  Standoff, .144 ID x 3/8 L, Brass 

Содержание VIP-LD

Страница 1: ...LATION and OPERATION MANUAL for VIP II BREWERS BREWER SPECIFICATIONS Model Width Length Height US 120V Amps CANADA 120V Amps VIP LD 8 5 8 16 5 8 17 1 2 13 11 7 VIP TD 8 5 8 16 5 8 23 3 4 13 11 7 NOTE Automatic models without faucet is also available Model VIP LD ...

Страница 2: ...rew cycle will begin Otherwise the brewer will go into the autoarm mode In the autoarm mode the heating light will be lit and the corresponding switch light will begin to flash indicating that the unit is in the brew mode but is not up to temperature When the tank reaches the preset temperature the brew cycle will begin Note To accelerate the set up time the Tank Temp adjustment dial may be rotate...

Страница 3: ... and hold the appropriate brew switch for 3 seconds until brewing begins Do not remove dispenser Brew cycle may be canceled by depressing the cancel switch The heating and brew switch light should no longer be flashing 7 Hot water will be delivered through the sprayhead This distributes the hot water evenly over the coffee bed within the brew basket The coffee brew will drain from the brew basket ...

Страница 4: ... are positioned above the fill valve Refer to wiring diagram on page 6 The autoarm feature may be bypassed for individual brew cycles by holding in the brew start switch for about 3 seconds Release switch when brew cycle starts Visa Brew Continues to flash the brewing light after the fill portion of the brew cycle has stopped alerting the user that the brewed hot coffee has not finished draining f...

Страница 5: ... Disable Auto Arm Autobrew Heating half brew lights on steady Temperature Probe Thermistor is open Replace Thermistor Autobrew Heating full brew lights on steady Temperature Probe Thermistor shorted Replace Thermistor IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR THE BREWER CAN BE RESET BY HOLDING DOWN THE CANCEL BUTTON FOR APPROXIMATELY 5 SECONDS ERROR WILL CLEAR REPLACEMENT PARTS LIST Par...

Страница 6: ...material or workmanship and returned to our factory shipping cost prepaid No warranty expressed or implied other than the aforesaid is made or authorized by Newco Enterprises Inc Prompt disposition will be made if item proves to be defective within warranty Before returning any item write or call Newco or the dealer from whom the product was purchased giving model number serial number and date of ...

Отзывы: