Newco VIP-LD Скачать руководство пользователя страница 4

BREW SYSTEM DESIGN FEATURES  

 

FEATURE SUMMARY TABLE 

Feature Settings 

Available 

Controls/Indicates 

Brew Time 

30-300 seconds (.5-5 minutes). 

Volume of water delivered for coffee. 

Visi-Brew 

30-240 seconds (.5-4 minutes). 

Duration of flashing brewing light after brew time 
elapses to indicate coffee still draining from basket. 

Temperature 

170-208

°

 F. 

Water temperature in tank. 

Autoarm 

On or Off; (Wiring determines value). 

Flashes heating light when heating and brew switch is 
depressed. 

Power Modes 

Power Save; Adjustable 30-240 mins. 

Tank temperature reduced to 170

°

 F after set time. 

Use "RUN TIME..." DIAL 

Normal. Default when dial is in off position. 

Maintains tank at set temperature. 

 

Digital Brew Timing - Brew time is accurate to within .1 seconds over the entire adjustment range of 30 to 360 
seconds. 

 

AutoCal Function - Allows the brew volume to be set with one brew cycle. To use feature it is best to remove the 
brew basket due to the delay in cessation of the sprayhead delivery and the final drainage from the brewbasket. If 
doing so place a wide mouth pitcher of suitable volume and with desired volume level indicated on pitcher below 
sprayhead to capture brewed water. Brew time adjustment knob may be turned all the way up and then a brew cycle 
started. During the brew cycle, as the volume approaches the correct level in the decanter, slowly rotate the dial 
down until brewing stops. The timer is now set for the delivered amount of water. (As an alternate to this temporarily 
replace the standard brewbasket with a basket which has had the outlet enlarged to allow the water to flow out as 
fast as it comes in. Do not use this basket for brewing coffee.) 

 

Auto Arm - Ensures that the brewer is up to temperature prior to brewing to ensure proper extraction is obtained. If 
the water temperature in the tank is below the value set by the "Solid State Thermostat" on the control board when 
the brew cycle is initiated the fill portion of the brew cycle is delayed. The heating light will begin to flash indicating 
that the unit is in the brew mode but is not up to temperature (brewing light will also be on). The tank heater will 
begin heating and when the tank reaches the preset temperature the fill portion of the brew cycle will begin. This 
feature may be disabled if desired by connecting the 1 pole connector with blue wire to the mating connector with 
red wire. Connectors are positioned above the fill valve. Refer to wiring diagram on page 6. The autoarm feature 
may be bypassed for individual brew cycles by holding in the brew start switch for about 3 seconds. Release switch 
when brew cycle starts. 

 

Visa-Brew - Continues to flash the brewing light after the fill portion of the brew cycle has stopped alerting the user 
that the brewed hot coffee has not finished draining from the brew basket. This popular feature has been enhanced 
with an autocal feature similiar to the brewing autocal described above. Simply turn the adjustment dial all the way 
up, start a normal brew cycle as described under the "OPERATION INSTRUCTIONS", and after the brewed coffee 
has quit dripping from the basket turn the dial down just until the brewing light turns off. Visa Brew is now custom set 
for your machine, filters, and coffee. 

 

Power Save Mode - Allows you to automatically save energy when the brewer is not in use for a specified length of 
time. In this mode the tank heater will be set back to 170

°

F after being idle for the selected time. To select the 

timeframe before power save mode is engaged, rotate the dial on the board labeled "Run Time Before System 
Shutdown" to the desired setting. If the dial is put in the off position the brewer fill be in a normal mode mode the 
tank temperature will be maintained at the temperature set on the control board at all times. Starting a brew cycle 
will reinitialize the timer and the set time frame starts over. If the autoarm has not been disabled the tank will be 
brought up to temperature before brewing when the brew start switch is depressed. 

 

Solid State Thermostat - Maintains temperature within 3 degrees throughout the adjustment range of 170-208 
degrees. Full off position is at the extreme left of the adjustment dial. The only wear item, a remotely mounted relay, 
may be replaced without disturbing the tank or re calibrating the temperature. This also allows the incorporation of 
several other convenience and safety features as explained below. 

 

Initial Tank Fill Circuit - Prevents the tank element from coming on before water level in tank has covered the 
element in the tank when setting the brewer up. This acts as a backup to the unique mechanical heater control 
incorporated into the brewers tank system to ensure that the tank element or its components are not damaged by 
premature heatup. The fill solenoid will run until water contacts the probe in the upper expansion chamber or for up 
to 6 minutes, whichever comes first. See "Tank Fill" under the "INITIAL SETUP INSTRUCTIONS" for operation. 

 

Содержание VIP-LD

Страница 1: ...LATION and OPERATION MANUAL for VIP II BREWERS BREWER SPECIFICATIONS Model Width Length Height US 120V Amps CANADA 120V Amps VIP LD 8 5 8 16 5 8 17 1 2 13 11 7 VIP TD 8 5 8 16 5 8 23 3 4 13 11 7 NOTE Automatic models without faucet is also available Model VIP LD ...

Страница 2: ...rew cycle will begin Otherwise the brewer will go into the autoarm mode In the autoarm mode the heating light will be lit and the corresponding switch light will begin to flash indicating that the unit is in the brew mode but is not up to temperature When the tank reaches the preset temperature the brew cycle will begin Note To accelerate the set up time the Tank Temp adjustment dial may be rotate...

Страница 3: ... and hold the appropriate brew switch for 3 seconds until brewing begins Do not remove dispenser Brew cycle may be canceled by depressing the cancel switch The heating and brew switch light should no longer be flashing 7 Hot water will be delivered through the sprayhead This distributes the hot water evenly over the coffee bed within the brew basket The coffee brew will drain from the brew basket ...

Страница 4: ... are positioned above the fill valve Refer to wiring diagram on page 6 The autoarm feature may be bypassed for individual brew cycles by holding in the brew start switch for about 3 seconds Release switch when brew cycle starts Visa Brew Continues to flash the brewing light after the fill portion of the brew cycle has stopped alerting the user that the brewed hot coffee has not finished draining f...

Страница 5: ... Disable Auto Arm Autobrew Heating half brew lights on steady Temperature Probe Thermistor is open Replace Thermistor Autobrew Heating full brew lights on steady Temperature Probe Thermistor shorted Replace Thermistor IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR THE BREWER CAN BE RESET BY HOLDING DOWN THE CANCEL BUTTON FOR APPROXIMATELY 5 SECONDS ERROR WILL CLEAR REPLACEMENT PARTS LIST Par...

Страница 6: ...material or workmanship and returned to our factory shipping cost prepaid No warranty expressed or implied other than the aforesaid is made or authorized by Newco Enterprises Inc Prompt disposition will be made if item proves to be defective within warranty Before returning any item write or call Newco or the dealer from whom the product was purchased giving model number serial number and date of ...

Отзывы: