15-Feb-17
NEI 1.800.325.7867 www.newcocoffee.com [Manual #: 600769]
P a g e
|
4
Introduction (Continued)
Audible Alert Mode – Provides an audible signal when coffee has finished brewing notifying everybody that
fresh coffee is available. May be turned on or off and set for 1-9 beeps.
Coffee Freshness Monitor – Monitors the elapsed time since the brew cycle to assure the coffee is fresh.
Freshness time may be set for 10 minutes to 2 hours. The last 10 minutes of the freshness time are counted
down on the display and when the preset time is reached a beep is sounded and the coffee monitor light
begins to flash.
Filtering Flow Rate – This is the flow rate of incoming water and is used to calculate the volume of water that
has been filtered. The flow rates may be turned off or set for .25, .50, .75 or 1.00 gallon per minute flow rates.
Note: A filter with a minimum flow rate of 1 GPM minimum is recommended. The left hand board provides the
monitoring function for both sides of the brewer.
Filter Capacity – The filtering capacity in gallons of the filter installed (optional) on the brewer may be selected
here. Capacity may be turned off or set for one of the following available values; 0, 500, 1500, 2000 or 2500
gallons.
Number of Brews – The number of brew cycles started may be tracked with this feature. The accumulated
number of cycles may be reset. Using the brew buttons, first display “Clr” when in the program mode, then
depress cancel.
Power Mode - allows you to automatically save energy when the brewer is not in use for a length of time
specified under power shutdown time. Available modes are normal, power save (standby) and power down.
The modes are described below.
•
Normal - In this mode the tank temperature will be maintained at the preset temperature at all times.
•
Power Save (Standby) - In this mode the tank temperature will be maintained at approximately 170
degrees when the set time has been reached. Brew 1 light will flash about once every 10 seconds to indicate
unit is in power save mode.
•
Power Down - In this mode the tank heater element will be disabled when the set time has been
reached.
Brew 2 light will flash about once every 10 seconds to indicate unit is in power down mode. By depressing the
brew start switch, the timer is reinitialized and the set time frame starts over. In standby and power down
modes the auto arm feature, if enabled, will bring the tank up to the preset temperature before brewing when
the brew switch is depressed.
Power Shutdown Time – This feature is used to set a specified length of time ranging from 30 to 240 minutes
before the standby or power down modes will take effect.
Please Note:
The digital control boards are the same board for both the left-hand and right-hand side of the brewer. The
board on the left-hand side however, requires a jumper across the center pins of the connector on the edge of
the board. This allows the software to recognize it as the master board for purposes of tank heater control, etc.