15-Feb-17
NEI 1.800.325.7867 www.newcocoffee.com [Manual #: 600769]
P a g e
|
6
Introduction (Continued)
Error Messages
The following table explains the error messages, which may be encountered, on the brewer. Going into the program
mode, using the brew button to display “Cir” and then pressing the cancel button will clear the error messages.
Error Message
Description
Cause
Er1
Fill run error
The fill solenoid has either run for more than six (6) minutes on the
initial tank fill or Three (3) minutes in normal operation.
Er2
Heater run error
The tank heater has run for more than 30 consecutive minutes.
Er3
Shorted probe
Short in the thermistor circuit.
Er4
Open probe
Break in the thermistor circuit.
Ful
Filter limit reached
The selected filtering capacity of the filter has been reached.
Wiring Diagram [Dual]