8
Installation Instructions
WARNING: - Read and follow installation instructions before
plugging or wiring in machine to electrical circuit. Warranty will
be void if machine is connected to any voltage other than that
specified on the nameplate serial tag.
Machine must be on a flat and level surface. Plug or wire in machine
to appropriate voltage as noted on the brewer serial tag. Serial tag
is located on inside of machine.
Brew water temperature is factory set at 180o F
Areas of high altitude will require lowering this temperature to
prevent boiling. This chart should be used as a guide when
readjusting the brew water temperature.
Altitude
(Feet)
Boiling point of
water o F o C
Recommended water
temperature o F o C
-1000
213.8 101.0
200 93.3
-500
212.9 100.5
200 93.3
0
212.0 100.0
200 93.3
500
211.1 99.5
200 93.3
1000
210.2 99.0
200 93.3
1500
209.3 98.5
200 93.3
2000
208.4 98.0
200 93.3
2500
207.4 97.4
200 93.3
3000
206.5 96.9
199 92.8
3500
205.6 96.4
198 92.2
4000
204.7 95.9
197 91.7
4500
203.8 95.4
196 91.1
5000
202.9 94.9
195 90.6
5500
201.9 94.4
195 90.6
6000
201.0 93.9
194 90.0
6500
200.1 93.4
193 89.4
7000
199.2 92.9
192 88.9
7500
198.3 92.4
191 88.3
8000
197.4 91.9
190 87.8
8500
196.5 91.4
189 87.2
9000
195.5 90.8
188 86.7
9500
194.6 90.3
187 86.1
10000
193.7 89.8
186 85.6