background image

User’s Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 5

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Parts Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Using the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 10

Regulations and standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ventilation & Mounting height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Method 1: Re-circulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Method 2: Extraction through an outside wall . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wall Fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Hood Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

1

Contents

Содержание 100 Chim Hood

Страница 1: ...Chimney Hood User Installation Instructions...

Страница 2: ...ber of options This indicates that your call has been accepted and is being held in a queue Calls are answered in strict rotation as the Customer Care Representatives become available When calling ple...

Страница 3: ...nce 5 Installation 6 10 Regulations and standards 6 Ventilation Mounting height 6 Method 1 Re circulation 7 Method 2 Extraction through an outside wall 8 Wall Fixing 9 Installation Illustrations 9 Hoo...

Страница 4: ...with these instructions and only be used for normal domestic purposes Please refer to your guarantee card for further details Please note that the guarantee and Service availability only apply to the...

Страница 5: ...wall bracket adjustable slider lamp covers removable grease filters motor light bulb Please note The lights on the Chimney hood may located either at the front of the hood or at the rear depending on...

Страница 6: ...ion To operate the hood press the button for the required speed select 1 low 2 medium or 3 high speed The neon indicator light if fitted will light up to show when the fan is operating To switch off p...

Страница 7: ...ter and dry with a clean towel 3 Refit the clean filters 4 Aluminium grease filters are supplied with this appliance Outer casing Stainless Steel All external parts of the outer casing and visor can b...

Страница 8: ...not of the balanced flue type Mounting height The cooker hood must be fitted at least 650 mm above a gas or electric hob If cooker hob instructions give a different figure to that given above then th...

Страница 9: ...rom the air ducting vents is not obstructed by cupboards shelves etc Do not vent into enclosed cupboard space This method may require you to pur chase carbon filters these are avail able from Customer...

Страница 10: ...mmend that a wall vent kit is purchased from your supplier or local hardware store Use a 125 mm diameter ducting kit and connect to the ducting outlet adaptor Horizontal duct runs should be avoided A...

Страница 11: ...junction pieces as shown Secure the top junction piece to the wall bracket through the side holes using the screws provided In some cases it may be necessary to adjust the length of one or both of the...

Страница 12: ...y piece including the hood body are as fol lows 250mm x 183mm x 590 960mm This is W x D x H Installation Body of hood Hood Name Width mm Depth mm Height mm 60cm Chimney Hood 600 485 190 70cm Chimney H...

Страница 13: ...s identifying the terminals in your spur box proceed as follows 1 The wire which is coloured blue must be connected to the terminal marked N neutral LOAD or coloured black 2 The wire which is coloured...

Страница 14: ...47 dBA Light bulbs 2 x 40 W Candle lamp small edison screw fitting Note If the hood is to be used for display purposes only we recommend the use of 25 W lamps Motor rating 120W Carbon filters x 2 avai...

Страница 15: ...ons This indicates that your call has been accepted and is being held in a queue Calls are answered in strict rotation as Customer Care Representatives become available Enter appliance numbers here fo...

Страница 16: ...fruit juices and espe cially salt they can mark or damage stainless steel if they are left on the surface Wipe any splashes immediately To maintain the finish of the stainless steel or to remove any...

Страница 17: ...15...

Страница 18: ...GLEN DIMPLEX HOME APPLIANCES STONEY LANE PRESCOT MERSEYSIDE L35 2XW 08 27136 01 08 2004 3LI0D2D302 5 D3...