Drain cover
Soft rubber
stopper
Drain hose
Back of the unit
Drain cover
Drain hose
1. Prepare the supplied drain hose to connect to the
continuous drainage cover.
2. Unscrew and remove the drain cover and the soft
rubber stopper.
3. Insert the drain hose through the hole of the drain
cover and connect drain hose and drain cover to the
drain port.
4. Tighten the drain cover in a clockwise direction onto
the rear of the unit.
CONTINUOUS DRAINAGE OPTIONS
3
1
2
Continuous drainage is an additional method of removing collected water from the dehumidifier.
Instead of manually emptying the water tank, the User may choose this method to allow the
water to bypass the water tank and flow directly from the dehumidifier via a drain hose or pump-
out drain hose.The following steps are useful when there are good conditions for drainage near
the dehumidifier.
Option 1
INSTALLING DRAINAGE HOSE
When using continuous drainage, the drain hose must be placed horizontally below the level of
the drainage hole. Avoid uneven ground and kinking the hose.
Option 2
Automatic pump-out operations
Installation:
1.Connect the attached continuous drainage adaptor
(fig. 1) to the drain hole on rear panel (fig. 2).
2.When the dehumidifier is in operation the water
will drain continuously and automatically.
Remove pump-out drain hose:
1.Press the drain hole (fig.3) on the unit.
2.The continuous drainage adaptor will detach from
the unit.
8