Shanghai New Rock Technologies Inc. Page39/75
Name
Description
Recording
Select if Recording is activated. The OM will record calls (including
incoming and outgoing calls) on this analog trunk when this function is
activated.
2.5.3
IP Trunk
Registration
After login, click “Trunking > IP Trunk Registration” tab to open the configuration interface.
Figure 2-14
Registration configuration interface of IP trunk
Table 2-13
Registration configuration parameter of IP trunk
Name
Description
Signaling Port
Configure the SIP port, with its default value 5060.
Note: The signaling port number can be set in the range of 1-9999, but
cannot conflict with the other UDP port numbers used by the equipment.
Registration
Server
Configure the address and port number of SIP registration server, and the
address and port number are separated by “:”. It has no default value.
The registration server address can be an IP address or a domain name.
When a domain name is used, it is required to activate DNS service and
configure DNS server parameters on the page of configuring network
parameters. For example: “201.30.170.38:5060”, “register.com:5060”.
Registration
expire
Valid time of SIP re-registration in second.
Proxy Server
Configure the IP address and port number of SIP proxy server, and the
address and port number are separated by “:”. It has no default value.
The proxy server address can be set to an IP address or a domain name.
When a domain name is used, it is required to activate DNS service and
configure DNS server parameters on the page of configuring network
parameters. Examples of complete and effective configuration:
“201.30.170.38:5060”, “softswitch.com:5060”.