1 Menu tree
1.4 MAIN MENU – Config
FST_HB.EN04/03
117
1.4 MAIN MENU – Config
All menu items with adjustable values can be deactivated by entering the
value “0”.
Menu item
Description
Setting range
Commissioning –
Calibration drive
Carry out calibration drive. During a calibration drive four
measuring drives are required for each drive speed. The
acceleration and braking behaviour for each speed is
determined automatically. The controller uses this information
to select the optimum speed and the correct braking point for
each drive.
³
YES
NO
Commissioning –
Learn drive
Carry out learn drive. During the learn drive, the car
automatically travels upwards through the entire shaft at
inspection speed. The controller determines the exact position
of the solenoids for solenoid switches “ZoneB”, “Corr.Bottom”
and “Corr.Top”. The levelling positions of the floors are
automatically centred in the door zones after the learn drive!
The learn drive is only required when using incremental
positioning.
³
YES
NO
Commissioning –
Set Floor [n]
The current position of the car is entered as a point of
reference for the entire shaft. The levelling positions of the
remaining floors are adjusted to the current position of the car.
0 ... top floor
Commissioning –
Correct-levelling
Correction of the levelling position on the floor where the car
is currently located. The measured value must be entered (car
is too high: positive sign +; car is too low: negative sign –).
-250 ... 250 mm
Commissioning –
Cal. V-tolerance
Measuring tolerance when measuring the speed of the
calibration run. The set value should only be changed after
consulting NEW LIFT. The calibration results are influenced
by the measuring tolerance.
1 ... 100 %
Commissioning –
Installation Mode
Suppresses error messages that would prevent installation
drives if the controller has not yet been fully commissioned.
Enables installation drives using the inspection and auxiliary
controls without connecting the sensor and the car control
module.
ON
OFF
Prio-Landing/Car –
Landing Prio. Type
Activation type “Priority Landing”.
-
Hard: All in-car and landing calls are deleted.
-
Soft: In-car calls remain, landing calls are deleted.
Hard
Soft
Prio-Landing/Car –
Landing Prio. Time
Delay for switching off “Priority landing” after reaching the
target floor.
0 ... 999 sec
Prio-Landing/Car –
Landing Prio. Prog.
Variations of “Priority landing”:
-
Auto 1: after reaching the target floor the “Priority landing”
state remains active until the next in-car call.
-
Auto 2: after reaching the target floor “Priority in-car” is
activated automatically.
-
Standard: when reaching the target floor the system
switches to normal operation after the “
Landing Prio.
Time
” has elapsed.
Auto 1
Auto 2
Standard
Prio-Landing/Car –
Car Prio. Type
Activation type “Priority car”
-
Hard: All in-car and landing calls are deleted.
-
Soft: In-car calls remain, landing calls are deleted if
Keep
landing calls = NO
is set.
Hard
Soft
Содержание FST
Страница 1: ...Manual Field Bus Controller ...
Страница 6: ...Table of Contents 4 FST_HB EN04 03 ...
Страница 43: ...4 Technical Data 4 2 FST Controller FST_HB EN04 03 41 Fig 4 2 FST Controller ...
Страница 98: ...4 Technical Data 4 13 Trailing cable 96 FST_HB EN04 03 Fig 4 14 Trailing cable version 1 ...
Страница 102: ...4 Technical Data 4 13 Trailing cable 100 FST_HB EN04 03 ...
Страница 104: ...1 Menu tree 1 1 General 102 FST_HB EN04 03 Fig 1 1 FST Controller menu tree part 1 ...
Страница 105: ...1 Menu tree 1 1 General FST_HB EN04 03 103 Fig 1 2 FST Controller menu tree part 2 ...
Страница 106: ...1 Menu tree 1 1 General 104 FST_HB EN04 03 Fig 1 3 FST Controller menu tree part 3 ...
Страница 107: ...1 Menu tree 1 1 General FST_HB EN04 03 105 Fig 1 4 FST Controller menu tree part 4 ...
Страница 108: ...1 Menu tree 1 1 General 106 FST_HB EN04 03 Fig 1 5 FST Controller menu tree part 5 ...
Страница 109: ...1 Menu tree 1 1 General FST_HB EN04 03 107 Fig 1 6 FST Controller menu tree part 6 ...
Страница 110: ...1 Menu tree 1 1 General 108 FST_HB EN04 03 Fig 1 7 FST Controller menu tree part 7 ...
Страница 111: ...1 Menu tree 1 1 General FST_HB EN04 03 109 Fig 1 8 FST Controller menu tree part 8 ...
Страница 112: ...1 Menu tree 1 1 General 110 FST_HB EN04 03 Fig 1 9 FST Controller menu tree part 9 ...
Страница 138: ...1 Menu tree 1 5 MAIN MENU Positioning 136 FST_HB EN04 03 Fig 1 14 Parameters for linear positioning ...
Страница 139: ...1 Menu tree 1 5 MAIN MENU Positioning FST_HB EN04 03 137 Fig 1 15 Additional parameters for incremental positioning ...
Страница 145: ...1 Menu tree 1 7 MAIN MENUE System FST_HB EN04 03 143 Event Channels Fig 1 17 Event Channels of the FST Controller ...
Страница 149: ...1 Menu tree 1 8 MAIN MENUE Doors FST_HB EN04 03 147 Door times diagram Fig 1 18 Door times of the FST Controller ...
Страница 160: ...6 Error List 6 4 Error messages 158 FST_HB EN04 03 ...